3

E-PLEX 5x10 Exit Trim Model

The E-Plex Exit Trim Lock is adapt-

able to a wide variety of the more

popular exit devices on the market

today. No tools are required to

reverse handing, and the spring

loaded tailpiece drive automatical-

ly adjusts to door thicknesses

from 1

3

4

" to 2

1

8

". A door thick-

ness of up to 2

1

4

" inches can be

accommodated through the addi-

tion of a spacer ring. The E-Plex

Exit Trim accommodates through

bolt mounting as used in most fire

rated installations as well as sur-

face mounted applications and is

retrofittable to existing installa-

tions. Before beginning installa-

tion, please read and understand

all of the following instructions as

well as the respective exit device

manufacturer’s instructions.

Summary of Contents for E-Plex 5X10

Page 1: ...5X10 EXIT TRIM MODELS INSTALLATION INSTRUCTIONS...

Page 2: ...Models 9 J Installing E5x00 Exit Trim 11 K Installing The Battery Pack and Cover Changing Batteries 12 L Testing the Operation of the Lock 13 M Reset Function 14 Warning The Master Code of this lock...

Page 3: ...from 1 3 4 to 21 8 A door thick ness of up to 21 4 inches can be accommodated through the addi tion of a spacer ring The E Plex Exit Trim accommodates through bolt mounting as used in most fire rated...

Page 4: ...s handing is properly set only a downward rotation of lever will actuate latch 2 Key Override Use The key override differs in that rotating the key does not actuate the latch To use the key override t...

Page 5: ...strike and drilling the exit device mounting holes Do not mount the exit device until completing Section B of this manual A 2 For Existing Installations New Installations proceed to Section B It is im...

Page 6: ...dy have a through bore at the intersection of the Vertical and Horizontal Centerlines if the existing hole is smaller than 2 1 8 54 mm in diameter it will need to be enlarged Extra care should be used...

Page 7: ...tside Unit Assembly b using the four 10 24 x 3 4 long screws c supplied in the accessory kit F LOCK HANDING F 1 Determine the handing of your door from the following diagram F 2 To set the handing of...

Page 8: ...substituted with a foreign part If the lock is used with a wall bumper the warranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditi...

Page 9: ...CONTROL 2941 INDIANA AVENUE WINSTON SALEM NC 27199 3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 1563 POSTAGE WILL BE PAID BY ADDRESSEE WINST...

Page 10: ...Exercise Room This lock is New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other t...

Page 11: ...Notes...

Page 12: ...our KIL cylinder You must use a Kaba tailpiece The K 2 tailpiece is preassembled with the Kaba 1599 G 3 Assemble the required tailpiece d supplied with your KIL cylinder All tailpieces must be install...

Page 13: ...de unit assembly follow the steps below H 4 Insert one of the supplied keys a into the outside lever b and rotate it counterclockwise 45 degrees Insert release tool d into the small hole e under lever...

Page 14: ...e Note You may want to use needle nose pliers for some tailpieces Insert the release tool d into the small hole f under lever as shown Gently push lever catch up until it clicks Remove tool then remo...

Page 15: ...ove tool then remove outside lever a J INSTALLING E5x00 EXIT TRIM Note Prior to mounting the lock ensure the handing is set correctly as the tailpiece may have shifted during handling see section F Wa...

Page 16: ...htening the LectroBolt to secure the lock to the door Note Do not shut door until installing batteries and testing operation as outlined in the following two sections K INSTALLING THE BATTERY PACK AND...

Page 17: ...ended position L 2 Enter the factory set combination 1 2 3 4 5 6 7 8 You see a green light and hear a tone as you push each button When the lock opens you will briefly hear the sound of an electric mo...

Page 18: ...und of lock resetting and a high pitch tone 6 Green light flashes Lock is reset to factory mode Note For security reasons all existing audit events are not deleted The lock is now set to the factory c...

Page 19: ...15 Notes...

Page 20: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com www e plexlock com PKG3055 0608...

Reviews: