Technical Manual
Design and function
27
04045376 - 05/2016
Kaba access manager 92 30
4.2.4
Function of the inputs
The function of the inputs depends on the configuration. The following functionali-
ties are possible:
Door frame contact
With a door frame contact, the access manager is able to detect if and how long the
door is open. If the maximum allowed door-opening time has elapsed and the door is
still open, the access manager sends an alarm record to the host computer. A relay
can be activated additionally.
Door opener key
A door-opener key can be connected if no subterminal is mounted in the interior and
if the door is not equipped with a door handle. If the door-opener key is pressed the
respective door-opener relay is activated.
Bolt contact
With the bolt contact, the access manager can identify the door’s current bolt posi-
tion. If the bolt is not in the expected position after the end of the allowed time, the
access control manager sends an alarm record to the host computer.
Door handle contact
With the door handle contact, the access manager can identify the door handle’s cur-
rent position. If the door frame contact responds without previous activation of the
door opener or pressing of the door handle, the access manager sends an alarm
record to the host computer.
Pass through
This input monitors if access has really taken place. To this end, a light barrier, con-
tact mat, etc., is connected to this input which reports if a person has passed
through.
The functions of door frame contact and door opener key are preset for the inputs
per access.
4.2.5
Function of the outputs
The function of the individual outputs depends on the configuration. Important func-
tions are:
Door-opener relay
A door opener can be connected to the door opener relay. The door-opener relay is
activated if the access manager releases access, e.g., after an authorized booking.
Alarm relay
Depending on the configuration, the alarm relay can be activated in case of an au-
thorized booking or alarm (e.g. door breakup).