Design and function
Technical Manual
26
04045376 - 05/2016
Kaba access manager 92 30
4.2.2
Superior system
Communication with the superior system (host computer) takes place via the Ether-
net network.
The superior system serves for centralized management of authorizations, access and
room profiles, system configuration and alarm management.
4.2.3
Reader
The data collection of identification data is performed via external readers.
Up to 2 readers can be connected. The readers which are supported depend on the
device variant.
Kaba access manager 92 30 with connections for readers via Wiegand
Kaba access manager supports the connection of two readers via the Wiegand inter-
face.
•
Connection individually via Wiegand interface
•
Data collection of identification data
•
Control of optical and acoustic signal generators
•
Power supply via the access manager
Kaba access manager 92 30 with connections for registration units and readers
via RS-485
The Kaba access manager supports connection of two Kaba RFID registration units
via the coaxial cable.
Alternatively, up to 2 readers/subterminals can be connected via the RS-485 inter-
face.
Registration unit:
•
Connection individually via coaxial cable
•
Data collection of identification data
•
CardLink validation and update
•
Control of optical and acoustic signal generators
•
Keypad is supported
•
Power supply via the access manager
Readers via RS-485:
•
Connection via RS-485 partyline in bus or star wiring
•
Data collection of identification data
•
CardLink validation
•
Control of optical and acoustic signal generators
•
Keypad is supported
•
The inputs and outputs of subterminals can be used.
•
Power supply via the access manager possible