PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL
27
It means fire put out automatically during
t the operation, when the exhaust gas
t temperature is below 40-45degree.
Such as: 1.There has no fuel at hopper.
2.
2.Auger motor is broken and stop feeding
th
fuel.
It means Igniter failure at the beginning.
Such as: 1. there have clinkers in fire pot.
2. The fire pot has not put right.
3. The switch which is located beside the
combustion fan to test the exhaust gas temperature
sensor, is broken,
4. The igniter is broken
It means there is earthquake during the
operation time. or You tilt the stove. Only
for the Japan version
Problem for the temperature sensor.
Unplug or broken or water temperature is too high
(This function only for the pellet stove with hot
water)
It means that there are some problems with
vacuum Switch.
Such as door has not been closed properly;
Combustion fan's speed cannot Speed up;
There is some leakage about the stove or
exhaust pipe is blocked and so on.
It means that the high temperature sensor
,
which
is located below the hopper, has some problem,
Such as: 1. the switch is broken,
2. The temperature is too high that the stove runs
not properly
During
the
operation,
the
stove
is
interrupted by electronic cut.
It means you need to cleaning the stoves.