12 

If  selecting  ―active‖,  the  objects ―date‖  and  ―time‖  will  visible,  the  date  and  the  time  can  be 

modified via them. 

 

Temperature setting 

The following parameters are used to set temperature display in the TFT operation system.   

Parameter “Temperature display units” 

Here set temperature display units. Options: 

Celsius (C)             

Fahrenheit ( F)       

1.

 

Indoor temperature setting 

Parameter “Type of indoor temperature sensor” 

Here set the type of indoor temperature sensor. Options: 

Internal temperature sensor   

External temperature sensor   

If selecting ―Internal temperature sensor‖,  measure the indoor temperature  via the temperature 

sensor in the TFT device, and the measure value can be sent or read to the bus via the object ―Indoor 

actual temperature‖ and can be displayed in the TFT operation system.   

If  selecting  ―External  temperature  sensor‖,  measure  the  indoor  temperature  via  the  external 

temperature sensor, the TFT receives the  measure  value via the object ―Indoor actual temperature‖ 

from the external temperature sensor and displays it. 

The internal temperature sensor is built-in the TFT device. The  TFT will generate heat  during 

working, this may affect the sensor to measure temperature, and the measure value may inaccurate. 

If  you require a more accurate temperature, you can select to use the External temperature sensor, 

and it can measure indoor temperature, and send the  measure value to the TFT, then the TFT will 

display the temperature.   

— 

Parameter “Indoor temperature change send at (Celsius)” 

The  parameter  is  visible  if  the  option  ―Internal  temperature  sensor‖  is  selected  with  the 

parameter  ―type  of  indoor  temperature  sensor‖,  it  is  used  to  set  how  much  the  door  temperature 

change, the related object will send the current temperature to the bus. Option:   

Do not send           

0.5                         

1                             
… 

If selecting ―Do not send‖, the  measure temperature will not be sent to the bus automatically, 

unless via the object ―Indoor actual temperature‖ read it.   

With  the  setting  ―3‖,  when  the  temperature  changes  of  3

,  the  object  ―Indoor  actual 

temperature‖ will send out the current temperature on the bus.   

— 

Parameter “Monitoring time of external sensor (min)” 

Summary of Contents for CHTF-05

Page 1: ...Guangzhou Video Star Electronics Europe K BUS Colour Touch Panel 5 0 User manual Ver 1 CHTF 05 01 1 Intelligent installation systems video star electronics eu ...

Page 2: ...mmunication object General Setting 41 6 2 Communication object Lighting 42 6 3 Communication object Blind Shutter 43 6 4 Communication object Scene 44 6 5 Communication object HVAC 44 6 6 Communication object Customize 46 6 7 Communication object Audio 46 6 8 Communication object Air condition 48 6 9 Communication object Security 50 6 10 Communication object RGB LED dimming 51 6 11 Communication o...

Page 3: ...mantle it then push it oppositely and pull it out gently Please note program the physical address before installation This manual provides detailed technical information about the TFT for users as well as assembly and programming details and explains how to use the TFT by the application examples The TFT is connected to the bus via the EIB connection terminals and need a 30V DC additional supply v...

Page 4: ... connection terminal grey yellow Cable cross section Single core 0 2 6 0mm2 Multi core 0 2 4mm2 Operating and display Programming LED and button For assignment of the physical address Green LED flashing Indicate the device running normally OK Screen reset button Restart TFT display system Temperature Operation 5 C 45 C Storage 25 C 55 C Transport 25 C 70 C Ambient condition Humidity 93 except dewi...

Page 5: ...gramming button Red LED for entering the physical address green LED for application process normally running KNX EIB bus connection terminal External power supply connection terminal IR transmitter probe proximity function now unavailable Indicator LED IR receiver probe proximity function now unavailable SD card Internal temperature sensor ...

Page 6: ...ed for movement lamella adjustment of a blind or a shutter provide up to 6 blinds shutters control Scene The function is used for recalling and storing a scene provide up to 18 scenes control HVAC control HVAC can be used for controlling an actuator on the bus to regulate room temperature according to the room of the use or requirements of the users Sending of customize values The function can be ...

Page 7: ...tion The function has two logic inputs input1and input2 provide three standard logic operation AND OR XOR Input1 makes logic operation with input2 and then the result is sent via output For example via the application control staircase lighting if you want to turn on the lighting when anyone pass the staircase But it is not necessary to carry out this action if it is enough brightness unless it is...

Page 8: ...lace where the TFT is mounted is known easily in the evening Options Off On Parameter Operation password This parameter is used to set operation password After the TFT executes block operation if you want to operate the TFT again you need enter into the password It also can be used to disarm when the security is activated see chapter 5 9 If you want to open the setting window you also need enter i...

Page 9: ...e delay has passed the backlight of screen will be changed to the brightness that is set in the follow parameter backlighting day night when does not under operating Option 5 6000 s Parameter Switch on delay of the screen saver s This parameter is visible if the option inactive has not been selected with the parameter screen saver It is used to set how long time delay to switch on the screen saver...

Page 10: ...ve two parameters Note after bus voltage recovery or reset if the object day night mode has not received a telegram value when the TFT is operated the backlight is changed from brightness of recovery to brightness of day Parameter backlighting day when does not under operating This parameter defines the backlighting of day when the TFT does not under operating Option 0 100 Parameter Backlighting n...

Page 11: ...tching to night at hour 0 23 minute 0 59 The parameter defines the time that the backlight switches from day to night mode automatically e g with 18 30 then when the time to 18 30 the backlight of screen switches to night mode automatically Parameter Time for switching to day at hour 0 23 minute 0 59 The parameter defines the time that the backlight switches from night to day mode automatically e ...

Page 12: ...al temperature from the external temperature sensor and displays it The internal temperature sensor is built in the TFT device The TFT will generate heat during working this may affect the sensor to measure temperature and the measure value may inaccurate If you require a more accurate temperature you can select to use the External temperature sensor and it can measure indoor temperature and send ...

Page 13: ...indoor temperature calibration i e the TFT will correct the temperature that the indoor temperature sensor detects to avoid the measure temperature with the actual temperature is too large error Option 128 127 If the correction value is 50 the sensor detects a temperature of 20 then the corrected temperature is 20 50 0 1 25 Parameter Temperature units of measurement The parameter is visible if the...

Page 14: ... bus voltage recovery or reset if the TFT has not received a temperature measure value from outdoor temperature sensor it will not show the outdoor temperature until received a temperature 5 2 Parameter window Lighting Parameter window Lighting can be shown in fig 5 2 Here can set up to 18 lighting controls and their parameters are the same for each lighting control which can be used to set the fu...

Page 15: ...ming Parameter Lighting x x 1 18 This parameter defines whether the lighting x is active Options Active Inactive If selecting active the following parameters will be visible Parameter Lighting x function The parameter is used to set the function of lighting x Options Switching Dimming ...

Page 16: ...d then a short operation will trigger a telegram on Parameter Name of light x This parameter is used to set the name that is shown in the TFT operation system for lighting x at most 10 characters can be input here Parameter Icon number of light x This parameter is used to set the icon number that is shown in the TFT operation system for lighting x which corresponding a relevant image You can refer...

Page 17: ... window Blind Shutter Roller blind Parameter Blind Shutter x function x 1 6 This parameter defines whether blind shutter x control function is active Options Active Inactive If selecting active the following parameters will be visible Parameter Name of blind shutter x ...

Page 18: ...ts adjustment and no need to distinguish long operation and short operation Parameter Duration of long operation entry 0 1s This parameter is visible if the option shutter is selected with the parameter function switchover blind shutter It is used to define the time which a long operation is recognized Option 3 30 5 4 Parameter window Scene Parameter window Scene can be shown in fig 5 4 Here can s...

Page 19: ...e function scenes It is used to set whether the scene storage function is enabled Options Inactive Active With the setting Active the following parameter Duration of long operation entry 0 1s will be visible The object Number of scene can send a telegram of storage scene via a long operation Parameter Duration of long operation entry 0 1s This parameter will be visible if the option active is sele...

Page 20: ...t heat protection Parameter Object for Operation mode change This parameter is used to define the size of the object for the RTC operating Options 1bit 1byte With the setting 1bit the 1 bit objects Frost heating protection mode Night operating mode and Comfort operating mode will be visible Room temperature controllers can be switch to different operating modes via the objects if the telegrams val...

Page 21: ... start Parameter Time of cyclical sending setpoint min This parameter is only visible if the option Send cyclically is selected with the above parameter Send setpoint value It is used to set the interval time between two temperature setpoints that are sent cyclically Option 1 60 Control function setting Parameter Control function This Parameter is used to set control function for room temperature ...

Page 22: ...meter Control function It is used to set the control function after bus voltage recovery or reset Options Heating Cooling In the case of heating and cooling function the object Switchover heating cooling can be used for the two functions switchover Parameter Setpoint temperatures for operating modes This parameter defines whether the temperatures setpoint refers to relative setpoint or absolute ...

Page 23: ...e heating Celsius Parameter Setpoint standby Cooling incremental Celsius These parameters are only visible if the option relative is selected with the parameter setpoint temperatures for operating modes The standby setpoint allows you to specify the number of degrees Celsius that the base setpoint is raised or lowered during standby mode for the heating cooling For example here set 3 for the stand...

Page 24: ...emperature may not be fallen below the temperature If the current temperature undershoots the configured value the room temperature controller triggers a control value telegram that cases the relevant heating actuator to heat up the room to prevent damage to the heating system from frost related cooling vice versa Option 5 40 Control type setting Parameter Control type heating Parameter Control ty...

Page 25: ...25 2 point 1 bit Off On 2 point 1 byte 0 100 PI continuous ...

Page 26: ...26 PI PWM 1 bit ...

Page 27: ... or 100 to open the temperature control valves and sends out a telegram off or 0 to close the valves If selecting inverse the object Heating Cooling control value sends out the negated control value For example the object sends out a telegram off or 0 to open the temperature control valves and sends out a telegram on or 100 to close the valves Note if the control type of 1bit the object Heating Co...

Page 28: ...setting for the cyclic time is the half of the monitoring time of the heating cooling actuator Parameter PI automatic tuning The parameter defines whether the PI automatic tuning is active Options Inactive Active If active PI parameter values can be taken via the Auto Tuning function which have been set within the application program rather than set via the follow parameters If inactive PI paramet...

Page 29: ... indoor temperature or damage the valve Option 0 255 Note the max PI control value must be higher than the min PI control value In the case of PI PWM if cooling when the current temperature is higher 2 C than the setpoint then ignore P and I values and the min max PI control values the valve will be fully opened or closed to extreme cool to make the temperature drop to the setpoint quickly if heat...

Page 30: ...ter is used to set the interval period which the object values will be send out on the bus via an operation in the TFT system for a group Options 10 50 Parameter Group x x A R This parameter defines whether the group x is active Options Active Inactive If selecting active the following parameters will be visible Parameter Name of group x This parameter is used to set the name that is shown in the ...

Page 31: ...t specifies the value range Options 1bit 1byte 0 100 1byte 1 255 2byte signed 32768 32767 2byte unsigned 0 65535 2byte float 671088 64 670760 96 Parameter Value of value y This parameter is used to specify value of value y that is sent for an operation in the TFT system The value range is dependent on the selected data type 5 7 Parameter window Audio Parameter window Audio can be shown in fig 5 7 ...

Page 32: ...playing music or turn off the audio Option 10 3600 When the object on off sends or receives a telegram off the sleep mode will be interrupted The sleep mode as a regular play function when the duration time has passed the audio is stopped or turned off Parameter When time for sleep is over This parameter defines whether only stop playing or turn off the audio when the duration time has passed for ...

Page 33: ...ription in this section The functions for controlling air condition in the TFT system are similar with the functions on the air conditioning remote control The users can learn the functions on the air conditioning remote control to an IR emitter on the bus via an IR learner then the application in the TFT should be configured correspond to functions of the IR emitter Now via the application of the...

Page 34: ...s Options No Yes With the setting Yes the setpoint can be changed via the object Setpoint Parameter Send setpoint value This parameter is used to set how to send the temperature setpoint value to the bus via the object Setpoint Options No send Only after change Send cyclically If no send is set the setpoint value will always be updated but not sent With the Only after change setting the setpoint v...

Page 35: ...on object chapter description about air condition With the 1byte setting the commands for control air condition are sent out via a 1 byte object IR command number The object value corresponds to each command is set via the following parameters Parameter Command for air condition on The parameter defines the value that the object IR command number sends out for air condition on Option 0 255 Paramet...

Page 36: ...d number sends out for wind mode auto Option 0 255 Parameter Command for wind mode stop The parameter defines the value that the object IR command number sends out for wind mode stop Option 0 255 Parameter Command for setpoint for heating cooling x x 16 31 Celsius The parameter defines the value that the object IR command number sends out for temperature setpoint x for heating cooling Option 0 255...

Page 37: ...eter is used to set the name that is shown in the TFT operation system for security x at most 10 characters can be input here Parameter Working mode of security x 1 6 This parameter is used to define the working mode of security x Options Arming 0 disarming 1 Arming 1 disarming 0 If selecting Arming 0 disarming 1 when the object disarming arming sends a telegram 0 a arming will be executed When th...

Page 38: ...eter window RGB LED dimming Parameter RGB LED dimming active This parameter defines whether RGB LED dimming function is active Options Active Inactive If selecting active the following parameter will be visible Parameter Interval period entry 0 1s This parameter is used to set the interval period which each group object including R G and B dimming objects sends out their values on the bus Options ...

Page 39: ...te when receiving a new object value as the final output The operation result can be set delay sending via a parameter Their parameters are the same for each logic operation function Take a logic operation as an example describing their parameter Fig 5 11 parameter window Logic Parameter Logic x active x 1 5 This parameter defines whether logic function x is active Options Active Inactive If selec...

Page 40: ... object input1 2 is negated and then Participate in operation Note the initialized value is not inversed Parameter Object type of output The parameter is used to define the size of the output objects output for output logic operation result Options 1byte 1bit Parameter Output default value true type This parameter is used to define the value that the object output should be output if the logic ope...

Page 41: ... function in the following 6 1 Communication object General Setting Note C in Flag column in the below table means enable the communication function of the object W means value of object can be written from the bus R means the value of the object can be read by the other devices T means the object has the transmission function U means the value of the object can be updated Fig 6 1 communication ob...

Page 42: ...is used to read the measure temperature or send it to the bus according to the parameter setting 3 Indoor actual temperature General 2Byte C W This communication object will be visible with external temperature sensor in the parameter type of indoor temperature sensor which is used to receive a telegram with the measure temperature from other external temperature sensor sending on the bus 4 Outdoo...

Page 43: ...ghting 6 3 Communication object Blind Shutter Fig 6 3 communication object Blind Shutter Shutter Fig 6 3 communication object Blind Shutter Roll Blind No Object function name Data type Flags 59 Travel Blind Shutter x 1bit C T The communication object is used to send out a telegram for the blind or shutter UP DOWN movement Telegram value 1 DOWN 0 UP 60 Adjust Blind Shutter x 1bit C T This communica...

Page 44: ...onds to the scene number 0 63 sent by the communication object Number of scene For example scene 1 in the parameter setup has the same output result as scene 0 in the communication object Number of scene Table 6 4 communication object Scene 6 5 Communication object HVAC Fig 6 5 communication object HVAC No Object function Name Data type Flags 89 Control on off HVAC 1bit C W The communication objec...

Page 45: ...an coil in the parameter control type heating cooling which is used to send out a telegram with control fan speed the telegram value is set via parameter Telegram value 0 100 0 255 94 Comfort operating mode HVAC 1bit C R W T The communication object will be visible with 1bit in the parameter object for operating mode change if a telegram 1 is sent out at this communication object the operating mod...

Page 46: ...VAC 1bit byte C R T The communication object is used to send out the control value for cooling function on the bus to control temperature controller on off Telegram value 2 point 1bit on off Telegram value 2 point 1byte 0 100 Telegram value PI continuous 0 100 Telegram value PI PWM 1bit on off Telegram value Fan coil 0 100 Table 6 5 communication object HVAC 6 6 Communication object Customize Fig ...

Page 47: ...e value Range from 0 to 100 157 pause Audio 1bit C W T The communication object is used to send out a telegram with temporarily halt playing Telegram value 1 pause 0 resume When the operating button play stop is stop status the button pause is disabled 158 Status volume Audio 1byte C W The communication object is used to receive status response with the volume from a music module on the bus and di...

Page 48: ...s repeat mode and shuffle mode are sent to the bus together if they are disabled then the player will play in sequence 164 Sound effect Audio 1byte C W T The communication object used to adjust the sound effect of music Telegram value 0 Hip hop 1 Knight 2 Dance 3 Popular 4 Classical 165 Song name Audio 14byte C W The communication object is used to receive the song name from a music module sending...

Page 49: ...ich is used to send out a telegram with control command of air condition the telegram values corresponds to different commands are set via the parameters 168 Mode heating cooling Air condition 1bit C T The communication object will be visible with 1bit in the parameter object type for control air condition which is used to send out a telegram with switching to the heating mode or the cooling mode ...

Page 50: ...e heating mode Telegram value 1 setpoint X 0 setpoint Y 182 189 Setpoint for cooling X Y Air condition 1bit C T The communication object will be visible with 1bit in the parameter object type for control air condition which is used to send out a telegram with the temperature setpoint X Y in the cooling mode Telegram value 1 setpoint X 0 setpoint Y Table 6 8 communication object table Air condition...

Page 51: ...on object is used to receive the brightness status of R red response 200 Status G RGB LED dimming 1byte C W The communication object is used to receive the brightness status of G green response 201 Status B RGB LED dimming 1byte C W The communication object is used to receive the brightness status of B blue response Table 6 10 communication object table RGB LED dimming 6 11 Communication object Lo...

Page 52: ...r temperatures and function blocks in the main interface There is a button in the top right side of main interface to enter the setting interface In the case of squares don t display temperatures To back to the main interface from the function interface via drop down page If the function interface has multi pages carry out pages turning by sideslip To enter the setting interface ...

Page 53: ... not available 7 3 Settings interface The settings interface is shown as the picture at right To enter modify each setting by clicking symbols at right Settings as follow Language There are 16 system languages but now only support Chinese and English Date modify date Main page style Cover flow and squares in the case of squares don t display temperature Time Modify time now the setting use 24 Hour...

Page 54: ...ts can be dimmed 0 1 2 3 4 5 6 7 General light Desk lamp Droplight Fluorescent lamp General light with dimming Desk lamp with dimming Droplight with dimming Fluorescent lamp with dimming 2 Operation interface The light control interface is shown as the picture at right Send a switch telegram via a short operation Entry dimming operation via a long operation depend on parameter setting Lamp ...

Page 55: ... the picture at right In the case of shutter send a blind up telegram via a long operation of left button and send a blind down telegram via a long operation of right button send a lamella up telegram via a short operation of left button and send a lamella down telegram via a short operation of right button In the case of blind send a blind open telegram via left button and send a blind close tele...

Page 56: ... 8 9 10 11 12 13 14 15 At home Cleaning Game All light off All light on Dinner Movie TV 16 17 18 19 20 21 22 23 Sleep Leave home Dance Sports Reception Read Music General 2 Operation interface The scene control interface is shown as the picture at right Recall scene via a short operation Storage scene via a long operation depend on parameter setting ...

Page 57: ...left In the case of different control functions and control types the operation interface will be different Temp Adjust the temperature setpoint of the current mode Mode Select different operation mode Speed There are high middle and low wind speeds to select C H Select the control function cooling or heating 7 8 Sending of customize value interface Icons of the function are the same as the icons ...

Page 58: ...Hop knight Dance Popular Classical Start stop Pause Volume decrease Volume increase 18 Song name display box 2 Operation interface The Audio control interface is shown as the picture at right If the Audio is switched off the operation interface will back to initial state power off and other operations are not available the current state is playing in the fig Sound effect hip hop knight dance popul...

Page 59: ...wind speed Middle wind speed High wind speed 9 10 11 12 13 14 Wind up down Wind auto Wind left right Wind stop Air condition on off Setpoint display box on off display 2 Operation interface The AC control interface is shown as the picture at right If the AC is switched off other operations are not available i e control telegrams will not be sent to the bus ...

Page 60: ...Open arming window Close arming window Open disarming window Close disarming window Armed Disarmed 2 Operation interface Arming disarming interface Already arming the icon shows green The current arming Open arming interface Open disarming interface and input password ...

Page 61: ...e current color is probably effect of R G and B three color mixtures If the three color LED lighting effect you need is similar with the colors of squares at the bottom of the interface you can click the corresponding color squares to recall it directly If you want to custom lighting effect you can adjust R G and B slider ...