38
SR-9080U
REC
REC
STOP
REC
CHECK
EJECT
OPERATE
REVERSE
FIELD REV
FIELD ADV
REW
PLAY
TRACKING
TIMER SEARCH
RESET/
CANCEL
DISPLAY LOCK
HDR
CNT RESET
MENU
TIME MODE
SHIFT
ON SCREEN
OPERATE
V. LOCK
PAUSE
FF
–
+
–
+
S E T
–
+
AL
TIME MODE
6-4 Alarm Recording
Alarm recording functions during timelapse recording. When an alarm signal is input to the rear panel’s ALARM IN terminal, an
index code is recorded on the tape and the VCR automatically switches to the 2H (SP) or 6H (EP) mode : U model, 3H (SP)
mode : E model for realtime recording of the alarm situation. Normal timelapse recording is restored after the preset alarm
recording duration has passed.
* Alarm recording will not start from the Pause mode.
* An index code (VISS) is recorded at the start point of the alarm recording as an alarm cue signal.
* During alarm recording, a +12 V signal is output from the rear panel’s ALARM REC OUT terminal.
* If a new alarm signal is input during alarm recording, alarm recording restarts from that point.
6 RECORDING
On-screen
"ALARM"
indication
Extinguished
Extinguished
Shown
Shown
Extinguished
Extinguished
Display "AL"
indication
Lit
Lit
Blinking
Blinking
Record mode
Timelapse
mode
Timelapse
mode
Timelapse
mode
2H (SP)/6H (EP) : U
3H (SP) : E
2H (SP)/6H (EP) : U
3H (SP) : E
Timelapse
recording
Timelapse
recording
Timelapse
recording
Alarm
recording
Alarm
recording
Alarm signal input
Alarm signal input
“AL” indication
5
Menu switches are provided for alarm recording mode,
alarm recording duration, buzzer ON/OFF in alarm
recording, and Forced Stop mode ON/OFF at tape end.
5
During alarm recording, the [AL] indication is lit on the
VCR and the [ALARM] indication is lit on the monitor
display. After alarm recording is complete, the “AL”
indication blinks on the display to show that an alarm
signal has been input.
* If the alarm recording function is activated a hundred
times a day or more, a malfunction may occur because
the guaranteed range is exceeded.
If you want to use this unit more than a hundred times a
day, set the recording speed mode to 2H, 6H, L12H,
L18H or L24H : U model, 3H, L12H or L24H : E model
and perform regular maintenance, replacing parts as
necessary.
39
6-4 Alarm Recording
4
Select the timelapse recording mode with the [TIME
MODE +/-] button on the front panel.
[
The selected recording speed mode is shown on the
VCR’s display and on the monitor.
5
Follow the procedure described in “Recording Basic
Operation” on page 30.
6
When an alarm signal is input to the rear panel’s
[ALARM IN] terminal, alarm recording is executed in
accordance with the specified settings.
7
To stop alarm recording and clear the [ALARM]
indication, press the [RESET/CANCEL] button.
• If the [RESET/CANCEL] button is pressed when the
[AL] indication is lit (during alarm recording), alarm
recording stops, the [AL] indication goes out, and
timelapse recording is restored. If the alarm buzzer is
on, the buzzer sound also stops.
• If the [AL] indication blinks and the [RESET/CANCEL]
button is pressed, the [AL] indication goes out.
8
The alarm input data can be checked in the main
menu’s <OTHER> menu (refer to page 21).
Display the alarm list screen and press the [RESET/
CANCEL] button to reset the alarm input data.
* There may be some picture distortion at the start
or end of an alarm recording. This is not a
malfunction.
Connect an alarm sensor to the rear panel’s alarm input terminal.
Preparation
1
Press the [OPERATE] button to turn the operating mode
on.
2
Open the main menu’s <ALARM/SENSOR MODE> and
set the alarm recording-related menu switches.
1
REC MODE
Set to “ALARM” or “ALL” to activate alarm recording.
• When set to “ALL”, both alarm recording and sensor
recording will be performed.
• The [ALARM] indication lights on the display.
2
REC SPEED
Select the alarm recording speed from the 2H (SP)
mode or the 6H (EP) mode.
3
DURATION
Set the alarm recording duration to 5 sec., 10 sec., 15
sec., 30 sec., 60 sec., 120 sec., 180 sec., TAPE END
(to tape end) or MANUAL (for as long as alarm
signals are input).
* When the alarm recording time is set to “MANUAL”,
the alarm cue signal (index code) will not be
recorded correctly if alarm input lasts for less than 5
seconds.
* When alarm recording duration is set with an
external switcher, set the alarm recording duration to
“MANUAL”.
4
TAPE END MODE
Selects whether or not the Stop mode is forcibly
engaged when the tape ends even if there is an alarm
recording during recording.
• When set to “STOP”, the Stop mode is engaged at
tape end even if repeat recording or auto rewind is
set.
• When set to “OFF”, VCR operation is determined by
the repeat recording or auto rewind setting.
3
Set the other menu switches.
5
Setting the alarm buzzer
Set the menu switch <AL/SENSOR IN> in
<BUZZER> to “ON” to sound the alarm buzzer during
alarm recording.
5
Setting the on-screen brightness and display
items
Select the monitor display setting with the menu
switch.
On-screen information is recorded together with the
video signals.
You can change the on-screen display position with
the [ON SCREEN
7
/
f
] buttons on the front panel.
5
Setting the HDR
To record in the HDR mode during timelapse
recording, set the menu switch <HDR> in <VTR
MODE> to “ON”.
6 RECORDING
[SRI/EXT MODE]
1. SRI/EXT REC OFF
2. EXT REC END NORMAL
3. CNT TAPE END OFF
[ALARM/SENSOR MODE]
1. REC MODE ALARM
2. REC SPEED 2H
3. DURATION 60SEC
4. TAPE END MODE OFF
Set to “ALARM” or “ALL”.
ALARM/SENSOR MODE screen
→
U model only