64
MENU SCREENS
CAMERA OPERATION Menu Screen
The CAMERA OPERATION menu screen is only displayed in the Camera mode.
Item
Function/Setting (bold characters indicate initial settings)
AE LEVEL
For adjusting the image level when using auto iris, “ALC” or “EEI”.
Increase value: Increases level.
Decrease value: Decreases level.
[Settings: –3, –2, -
NORMAL
(0) - 2, 3]
ALC MAX
Sets the maximum “ALC” value to automatically change the signal intensity level depending on the brightness.
[Setting: 6dB, 12dB, 18dB]
PRESET TEMP.
Sets the basic color temperature when the [WHT.BAL] white balance selector switch
c
on page 15 is in the PRST
(PRESET) position.
3200K
: Sets the basic color temperature to 3200K. (Use for light sources with a low color temperature,
such as halogen lamps.)
5600K
: Sets the basic color temperature to 5600K. (Use for light sources with a high color temperature,
such as sunlight.)
MEMO
This item does not function when the FAW item on the SWITCH MODE menu screen is set to “PRESET”.
SMOOTH TRANS
Smoothens the transition when the [GAIN] switch
b
on page 15, or
[WHT.BAL] switch
c
on page 15 is switched over and achieves gradual change in place of sudden change.
However, the smooth transition function does not function when switching the [GAIN] switch set in ALC, FULL AUTO
ON.
OFF
: Deactivates the smooth transition function.
ON
: Activates the smooth transition function.
BARS
Sets whether or not color bars are output. (This is fixed at “OFF” when in FULL AUTO mode)
OFF
: Color bars are not output.
ON
: Color bars are output.
PAGE BACK
The TOP MENU returns when the SHUTTER dial is pressed with the cursor at this position.
e_hd100.book Page 64 Thursday, July 14, 2005 5:28 PM
Summary of Contents for GY- HD101
Page 2: ......