3.4.4
VIEWFINDER adjustment
For the VIEWFINDER adjustment, the following adjustment are required only. Other adjustment items should be default
value.
1
VF COMMON
DC adjustment
ADJUST MENU
*
VIEWFINDER
-
JOG dial
+
Minimize the flicker
(1) Press the USER 1/2 button to select ADJUST
MENU No.93,”VF COMMON DC”.
(2) Rotate the JOG dial to adjust to the specified
level.
(3) Press the JOG dial to store the adjustment
data.
2
VF VCO
adjustment
ADJUST MENU
*
VIEWFINDER
-
JOG dial
+
Most stable point
for monitor screen
(1) Press the USER 1/2 button to select ADJUST
MENU No.95.”VF VCO L”.
(2) Rotate the JOG dial to adjust to the specified
level.
3
VF H-POSI-
TION
adjustment
ADJUST MENU
*
VIEWFINDER
-
JOG dial
+
Screen centering
(1) Press the USER 1/2 button to select ADJUST
MENU No.97,”VF H POSITION”.
(2) Rotate the JOG dial to adjust the marker to
horizontal center of the screen.
(3) Press the JOG dial to store the adjustment
data.
Gray scale chart
OK
NG
OK
NG
NOTE:
If adjustment cannot be done, change AD-
JUST MENU No. 96 “VF VCO H” to 3 or 5
and readjust.
(3) Press the JOG dial to store the adjustment
data.
50 %
50 %