62
EN
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
TROUBLESHOOTING
1.
No power is supplied.
2.
“SET DATE/TIME!”
appears.
3.
Recording cannot be
performed.
4.
There is no picture.
5.
Some functions are not
available using
MENU/
BRIGHT
.
6.
The focus does not adjust
automatically.
1.
• The power is not connected
properly.
• The battery is dead.
2.
• The date/time is not set.
• The built-in clock battery
has run out and the
previously set date/time has
been erased.
3.
— For Video Recording —
• The tape’s erase protection
tab is set to “SAVE”.
• The Power Switch is set to
“
” or “OFF”.
• The
VIDEO/DSC
Switch is
set to “
”.
• “TAPE END” appears.
• The cassette holder cover is
open.
— For D.S.C. Recording —
• The
VIDEO/DSC
Switch is
set to “VIDEO”.
• The camcorder’s built-in
memory is full.
4.
• The camcorder is not getting
power, or some other
malfunction exists.
5.
• The Power Switch is set to
“
”.
6.
• Focus is set to the Manual
mode.
• The recording was done in a
dark place, or the contrast
was low.
• The lens is dirty or covered
with condensation.
1.
•Connect the AC Power
Adapter/Charger securely
(
墌
pg. 9).
•Replace the dead battery
with a fully charged one
(
墌
pg. 8, 9).
2.
•Set the date/time (
墌
pg. 11).
•Consult your nearest JVC
dealer for replacement.
3.
•Set the tape’s erase
protection tab to “REC”
(
墌
pg. 12).
•Set the Power Switch to
“
” or “
” (
墌
pg. 15).
•Set the
VIDEO/DSC
Switch
to “VIDEO”.
•Replace with new cassette
(
墌
pg. 12).
•Close the cassette holder
cover.
•Set the
VIDEO/DSC
Switch
to “
”.
•Delete unwanted still
images (
墌
pg. 40).
4.
•Turn the camcorder’s power
off and on again (
墌
pg. 15).
5.
•Set the Power Switch to
“
” (
墌
pg. 15).
6.
•Set Focus to the Auto mode
(
墌
pg. 23).
•Clean the lens and check
the focus again (
墌
pg. 76).
If, after following the steps in the chart below, the problem still exists, please consult your nearest JVC dealer.
The camcorder is a microcomputer-controlled device. External noise and interference (from a TV, a radio,
etc.) might prevent it from functioning properly. In such cases, first disconnect its power supply unit (battery
pack, AC Power Adapter/Battery Charger, etc.) and wait a few minutes; and then re-connect it and proceed
as usual from the beginning.