1-46 (No.MA101)
4.2.7 Monitor adjustment (For J version)
CHROMA
PORT
INIT
CCFL
--------
--------
--------
--------
Color adjustment
(EEPROM data read/write of a monitor microcomputer)
Port output setting (This mode not using it by service.)
Monitor microcomputer shipment initialization setting
(This mode not using it by service.)
Backlight brightness setting (Fixed value B3)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Address
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Chrominance data
INPUT MODE/SW
PICTURE
COLOR
PHASE
CONTRAST
BRIGHT
GAMMA 0
GAMMA 1
OUT LIMIT
RGB AMPLITUDE
SUB-BRIGHT R
SUB-BRIGHT B
COM AMPLITUDE
COM BLANK LEV
DAC OUT
TINT
Minimum value
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Maximum value
3F
FF
3F
FF
FF
FF
FF
FF
1F
FF
FF
FF
FF
1F
FF
FF
Fixed value
Reference value
A5
3A
08
1F
7C
11
1C
2F
66
22
50
7F
60
D2
86
87
Cancellation of a test mode
Push the [STANDBY] key on the main unit.
[NEXT ] button
or
[PREVIOUS ] button
1. Switch on the main unit and insert a test disc (VT-501 or VT-502).
Play a 3TR(100% color bar) of the test disc and pause it.
2. In a state of procedure 1, set the main unit in a service mode. (See "5.1.3 Service mode setting procedure".)
3. Color bar is displayed to the monitor by pushing [MODE] button after having done select of [MONITOR] of the
service menu with the [NEXT ] or [PREVIOUS ] buttons, and the following indication goes in mini-LCD of
the main unit.
4. Select [CHROMA] and press the [MODE] button.
An address value and data value are displayed on the mini-LCD. (0 )
Press the center of the monitor to turn off the GUI screen.
5. Change data of each address with the [VOL+]/[VOL -] button while observing the color bar (Data value flashes
on and off in change operation.) and press the [MODE] button in order to write in data. (Adjust the fixed value
in the value of a following table. Besides it, set it in reference value and make a fine adjustment while observing
the monitor.)