AV-20N8
No. 56030
21
Measuring
Item
Test point
Adjustment part
instrument
Adjustment
●
Signal
11. V. HEIGHT
of
generator
V. HEIGHT
●
Remote
control
unit
Description
[ fv : 50Hz mode]
1.
Receive a cross-hatch signal.
2.
Select 2. V/C from the SERVICE MENU.
3.
Select 11. V. HEIGHT with the MENU
a
key.
4.
Set the initial setting value of 11. V. HEIGHT with the MENU
−
/
+
key.
5.
Adjust V. HEIGHT and make the vertical screen size 92% of
the picture size with the MENU
−
/
+
key.
DEFLECTION CIRCUIT ADJUSTMENT
●
There are 2 modes of adjustment (initial setting value) — 50Hz mode and 60Hz mode — depending upon the kind of signals (vertical
frequency 50Hz / 60Hz).
●
When adjusted in 50Hz mode, 60Hz mode will be automatically set.
The setting (adjustment) using the remote control unit is made on the basis of the initial setting values.
The setting values which adjust the screen to the optimum condition can be different from the initial setting values.
[SUB MENU 2. V/C (10. H. CENTER ~ 14. V. CENTER)]
Initial setting value
Setting item
Adjustment name
Variable range
50Hz
60Hz
10. H. CENTER
Horizontal center
−
16 ~ +15
−
10
−
10
11. V. HEIGHT
Vertical height
−
64 ~
+
63
−
15
0
12. V. LIN
Vertical linearity
−
16 ~ +15
0
0
13. V.S-CR
Vertical height correction
−
64 ~ +63
−
15
0
14. V. CENTER
Vertical center
0 ~
+
127
0 (Fixed)
0 (Fixed)
(to be continued)
: Do not adjust.
Screen size
Screen
size
92%
Picture size 100%
Picture
size
100%