Cerapur GC9000iW
6720813052 (2016/10)
ÿ Pull off the plug on the internal 3-way valve (if present).
of the controller.
is.
NOTE: Series connection.
• CR 10 remote control
ÿ For the assembly and combinability of the function modules, observe
the relevant installation instructions for the function modules.
ÿ Heating pump on connection terminal <PCO (ÿ Fig. 24, [3])
When the temperature monitor responds, heating and hot water operation
are interrupted.
ÿ Planning documentation and installation instructions
6.2.11 Storage tank charging pump connection
• Internet gateway MBLANi (can be ordered free of charge)
ÿ Cylinder temperature sensor on connection terminal 8TW1
[2] Function module 2 (external)
ÿ Connect temperature monitor.
6.2.3 Connecting the function module
6.2.6 Connection of outside temperature sensor
The following modulating controllers can be connected:
The EMS bus connector can be labeled either "RC", "BUS"
or "EMS".
ÿ External 3-way valve at connection terminal :PW1
ÿ If several external safety devices such as e.g. B. TB1 and
condensate pump are connected, they must be connected
in series.
ÿ Connect the circulation pump to connection terminal ;PW2 (ÿ Fig. 24, [4]).
The 230 V connections can be used for electrical
accessories in the heating systems. Each port has a
maximum allowable power consumption of 250 W.
6.2.4 Connection of several function modules
Contact the manufacturer for more information on other
controllers and modules that can be used.
ÿ Pull off the plug on the internal 3-way valve.
• Cascade module MC 400
6.2.10 Connect circulation pump
When installing the function module in the device, the cover
of the module box can only be installed again after an
opening has been exposed in the intermediate strut
[3] Connection terminals GC9000iW
[4] EMS BUS connection cable to the following function module
The circulation pump can be controlled by the control system.
• Systemregler CR 400, CW400, CW800
6.2.9 Connect external heating pump
The outside temperature sensor for the control system is connected to the
device.
(ÿ Fig. 24, [2]).
For heating systems with only underfloor heating and direct hydraulic
connection to the device.
The maximum permissible power consumption of modules
and pumps is 500 watts.
ÿ Connect the outside temperature sensor to terminal block 7T1 (ÿ Fig. 24,
[10]).
• Mixer module MM 100, MM200
Figure 25 Connection of several function modules
connect.
ÿ Use the EMS bus connection of the first module for the second module. To
do this, use the cable supplied with the module.
The address details are on the back of this document.
ÿ Connect the storage tank loading pump/external 3-way valve (230 V) to
terminal block :PW1 (ÿ Fig. 24, [2]).
(ÿ Fig. 24, [9]).
• External device module IGM
6.2.8 230 V connections (general)
6.2.5 Connect temperature monitor TB1 of the flow of an underfloor
heating
[5] Mains cable to the following functional module
A switchable heating circuit pump can also be connected
instead of a circulation pump. This pump is switched off
when hot water is being prepared via the internal 3-way
valve and the unit's internal pump.
• Rules CR 100, CW 100
The heating pump is always in operation during heating operation (parallel to
the pump installed in the device).
ÿ Observe the instructions for the respective product.
6.2.7 Storage tank temperature sensor connection
• Solar module MS 100, MS 200
[1] Function module 1 (installed in the device)
ÿ Remove bridge (ÿ Fig. 24, [14]) on connection terminal 6 .
Electrical connection | 17
6.2.12 External 3-way valve connection
ÿ Use the 230 V AC mains cable connection of the first module for the
second module. To do this, use the cable supplied with the module.
6 720 807 034-047.1TD
3
1
5
4
2
Machine Translated by Google
Summary of Contents for Cerapur 9000i
Page 41: ...6720813052 2016 10 Cerapur GC9000iW 41 notes Machine Translated by Google...
Page 42: ...6720813052 2016 10 Cerapur GC9000iW 42 notes Machine Translated by Google...
Page 43: ...Cerapur GC9000iW 6720813052 2016 10 43 notes Machine Translated by Google...
Page 45: ...Machine Translated by Google...