Transport
5
4
Installation
[m³]
4.1 Unpack the device
fill and top-up water
1
4
2
3
to fill.
ÿ Do not use well or ground water.
5.1
The water quality of the fill and top-up water is a key factor in increasing
the economy, functional reliability, service life and operational readiness
of a heating system.
ÿ At least 2 people are required to lift the device
The approved measure for water treatment is the full desalination of the
fill and top-up water with a conductivity of ÿ 10 microsie mens/cm (ÿ 10 ÿS/
cm). Instead of water treatment, a system separation can also be provided
directly behind the heat generator using a heat exchanger.
Figure 11 Proper lifting and carrying of the device
The electronically available document 6720841872
contains a list of approved antifreeze.
ÿ Only touch the device on the sides and not on the be
Unsuitable or dirty water can lead to sludge
formation, corrosion or calcification.
ÿ Cover the concentric flue gas adapter on the top of the device
Only remove the styrofoam floor after the device has
been hung up. As long as the device is not hanging, the
device can be safely placed on the floor.
put.
ÿ After working on gas-carrying parts: tight
[1] Maximum possible water volume over the service life of the heat
generator in m³
ÿ Transport the device to the installation site.
have it carried out by a specialist.
Installation, gas, exhaust gas and electrical connections
and commissioning of the system must be carried out by
an approved specialist company.
CAUTION: Personal injury and equipment damage from un
12 | Transport
[3] Use of untreated tap water in accordance with the TVO Drinking Water
Ordinance.
ÿ Remove and dispose of packaging material.
ÿ Replace used seals with new seals
antifreeze
[4] Use fully desalinated fill and top-up water with a conductivity of ÿ 10ÿS/
cm.
NOTICE: Damage to the heat exchanger or fault in
the heat generator or the hot water supply due to
unsuitable water!
Further information on water treatment can be obtained from the
manufacturer. The contact details can be found on the back of these
instructions.
necessary.
ÿ Treat fill and top-up water according to the specifications
in the following section.
You can use the document search on our website to
display them. You can find the address on the back of this
manual.
ÿ Flush the heating system before filling.
control panel or on the exhaust pipe connection (ÿ fig. 11).
This protects the connections from damage and/or dirt.
cken.
ÿ Attaching the device to a sack truck and locking it with a strap.
ÿ Only use the heating system with drinking water
water treatment
Figure 12 Requirements for fill and top-up water devices < 50 kW
WARNING: Explosion hazard.
ÿ Work on gas-carrying parts only by authorized persons
perform a health check.
[2] Total hardness in ° dH
ÿ Before working on gas-carrying parts: Close the gas
tap.
proper lifting.
Machine Translated by Google
Summary of Contents for Cerapur 9000i
Page 41: ...6720813052 2016 10 Cerapur GC9000iW 41 notes Machine Translated by Google...
Page 42: ...6720813052 2016 10 Cerapur GC9000iW 42 notes Machine Translated by Google...
Page 43: ...Cerapur GC9000iW 6720813052 2016 10 43 notes Machine Translated by Google...
Page 45: ...Machine Translated by Google...