EX4100 and EX4100-F Power System
IN THIS SECTION
AC Power Supply in EX4100 and EX4100-F Switches | 68
DC Power Supply in EX4100 Switches | 78
Power Supply LEDs in EX4100 Switches | 81
AC Power Supply in EX4100 and EX4100-F Switches
IN THIS SECTION
Characteristics of an AC Power Supply | 69
Specifications of the AC Power Supplies Used in EX4100 and EX4100-F Switches | 71
Specifications of the Power Cord for AC Power Supplies for EX4100 and EX4100-F Switches | 75
Juniper Networks ships EX4100 switches with one power supply installed in the rear panel. You can
install up to two power supplies in an EX4100 switch. The power supply slots are numbered 0 and 1,
and each slot has a power icon next to it. The power supplies support front-to-back airflow or back-to-
front airflow. They are fully redundant, load-sharing, hot-removable and hot-insertable field-replaceable
units (FRUs).
Hot-removable and hot-insertable mean that when the second power supply is installed
and running, you can remove and replace the power supplies without powering off the switch or
disrupting switch functions. This topic describes the AC power supplies that EX4100 switches support.
68
Summary of Contents for EX4100
Page 1: ...EX4100 and EX4100 F Switch Hardware Guide Published 2022 11 08 ...
Page 68: ...Figure 45 Front to Back Airflow Through the EX4100 48P or EX4100 48T Switch Chassis 59 ...
Page 69: ...Figure 46 Front to Back Airflow Through the EX4100 24MP or EX4100 48MP Switch Chassis 60 ...
Page 70: ...Figure 47 Front to Back Airflow Through the EX4100 F 24P Switch Chassis 61 ...
Page 71: ...Figure 48 Front to Back Airflow Through the EX4100 F 24T Switch Chassis 62 ...
Page 72: ...Figure 49 Front to Back Airflow Through the EX4100 F 48P Switch Chassis 63 ...
Page 209: ...5 CHAPTER Troubleshoot Hardware Troubleshoot the EX4100 and EX4100 F Components 201 ...