Table 11: Airflow Direction in EX4100 and EX4100-F Switch Models
(Continued)
Model Number
Fan Modules and Power
Supply
Direction of Airflow
•
EX4100-F-24P
•
EX4100-F-48P
Two built-in fans with AFO
cooling.
Front-to-back—cold air to
cool the chassis enters
through the vents on the
front panel of the chassis,
and hot air exits through
the vents on the rear panel
of the chassis.
EX4100-48T-AFI
The switch ships with two
fan modules and an AC
power supply, each with a
label AIR IN and a Juniper
Azure Blue handle.
Back-to-front—cold air to
cool the chassis enters
through the vents on the
rear panel of the chassis,
and hot air exits through
the vents on the front panel
of the chassis.
CAUTION: Do not mix:
• Power supplies with different airflow directions in the same chassis.
• Fan modules with different airflow directions in the same chassis.
• Power supplies and fan modules with different airflow directions in the same chassis.
If you install power supplies or fan modules with different airflow directions, Junos OS
raises an alarm.
Under normal operating conditions, the fan modules operate at a moderate speed.
Temperature sensors in the chassis monitor the temperature within the chassis.
If a fan module fails, or if the ambient temperature inside the chassis rises above the
acceptable range, Junos OS raises an alarm. If the temperature inside the chassis rises
above the threshold temperature, the system shuts down automatically.
56
Summary of Contents for EX4100
Page 1: ...EX4100 and EX4100 F Switch Hardware Guide Published 2022 11 08 ...
Page 68: ...Figure 45 Front to Back Airflow Through the EX4100 48P or EX4100 48T Switch Chassis 59 ...
Page 69: ...Figure 46 Front to Back Airflow Through the EX4100 24MP or EX4100 48MP Switch Chassis 60 ...
Page 70: ...Figure 47 Front to Back Airflow Through the EX4100 F 24P Switch Chassis 61 ...
Page 71: ...Figure 48 Front to Back Airflow Through the EX4100 F 24T Switch Chassis 62 ...
Page 72: ...Figure 49 Front to Back Airflow Through the EX4100 F 48P Switch Chassis 63 ...
Page 209: ...5 CHAPTER Troubleshoot Hardware Troubleshoot the EX4100 and EX4100 F Components 201 ...