4.5
Emergency Disconnect
CAUTION!
Faulty or non-accessible emergency disconnect switches can cause accidents
A faulty or non-accessible emergency disconnect switch can cause accidents.
u
The operation of the emergency disconnect switch must not be affected by any
objects placed in its way.
u
Report any defects on the emergency disconnect switch immediately to your
supervisor.
u
Mark the defective truck accordingly and take it out of service.
u
Do not return the truck to service until you have identified and rectified the fault.
Operating the emergency disconnect switch
Procedure
• Press the emergency disconnect switch (75).
All electrical travel, steering and hydraulic
functions are cut out.
75
Releasing the Emergency Disconnect
Procedure
• Press the rocker in (
s
) and pull the Emergency Disconnect switch (75) up until
you feel the Emergency Disconnect (75) switch engaging.
All electrical functions are enabled and the truck is operational again (assuming the
truck was operational before the Emergency Disconnect was pressed).