Approved application conditions
WARNING!
Do not exceed the permissible surface and point loading limits on the travel paths.
A second person is required as a lookout at blind spots.
The operator must ensure that the loading ramp/dock cannot move or come loose
during loading/unloading.
WARNING!
Use under extreme conditions
Using the truck under extreme conditions can result in malfunctions and accidents.
u
Special equipment and authorisation are required if the truck is to be constantly
used in extreme conditions, especially in dusty or corrosive atmospheres.
u
The truck cannot be used in areas at risk of explosion.
u
In adverse weather conditions (thunder, lightning) the industrial truck must not be
operated outside or in endangered areas.
– Operation in industrial and commercial environments.
– Permissible temperature range -20°C to 40°C.
– Operation only on secure, level surfaces with sufficient capacity.
– Do not exceed the permissible surface and point load limits on the travel routes.
– Operation only on travel paths that are visible and approved by the operating
company.
– Negotiating inclines up to a maximum of 15 %.
– Do not travel across or at an angle on inclines. Travel with the load facing uphill.
3.1
Internal Operation in Cold Stores with Cold Store Equipment (
o
)
In addition to the permissible operating conditions in industrial and commercial
environments, the truck remains primarily in cold stores. The truck should only leave
the cold store briefly to hand over a load.
– Permissible temperature range -30°C to +40°C.
– Maximum air humidity 95% non-condensing.
– Thawing is permissible only if the truck can be subsequently dried thoroughly.
– In cold store areas below -20°C the truck must be operated permanently and
should not be parked securely for more than 15 minutes.
– Do not charge the battery below +5°C.
13
10.20 en-GB
Summary of Contents for EFG 110
Page 2: ...2 ...
Page 4: ...4 10 20 en GB ...
Page 10: ...10 10 20 en GB ...
Page 23: ...Ast a 2 e a 2 W a c Q h 6 h 7 H 1 h 1 h 3 h 4 h 2 m 1 b L2 L1 y m 2 h 10 x 23 10 20 en GB ...
Page 38: ...38 10 20 en GB ...
Page 46: ...46 10 20 en GB ...
Page 56: ...The battery is now charged 56 10 20 en GB ...
Page 58: ...58 10 20 en GB ...
Page 63: ...72 71 73 69 74 75 70 69 68 67 66 64 65 63 63 10 20 en GB ...
Page 65: ...80 77 76 79 72 71 65 10 20 en GB ...
Page 172: ...172 10 20 en GB ...