4. OPERATION
27
DATA SAVE is a function for saving and restoring existing preset data and
editlist by using external storage devices. All data will be transferred via
AES/EBU interface. It is possible to use all storage medias which can be
connected via AES/EBU and which don’t change or manipulate audio data of
AES/EBU signal (f.i. DAT, audio file on workstation). The data block has a
duration of appr. 10 seconds. The header of data dump block is containing
number and name of data block. This is to be used to address determined
data block for saving or loading.
MODE
Selection of
MAINMENU
UTIL
Selection of
UTILITY
menu
DATA
Selection of DATA SAVE menu
save edl
Selection of data saving mode
display:
name edl nrxx e d i t l i s t
xx
Selection of data block (EDL) number for
(FREQ low section)
data saving (01...99)
ALL KNOBS
Changing of the default name (EDITLIST)
(low RANGE
into an individual name (10 digits), push to
... output GAIN)
generate space
or proceed without name changing (use of default name).
Start record function of connected external storage device (f.i.
DAT recorder)
FREQ/ENTER
Saving of data block
(low section)
display:
save edl nr**
< name >
After appr. 10 seconds data saving is finished. The unit returns
automatically to normal working mode. Then you can stop
recording of data at external storage device.
DATA SAVE
SAVING
PRESET AND EDL
DATA
pus h
pus h
pus h
pus h
turn
pus h
turn