Switch on brightness
undershoot

On, Off
Basic setting: Off

Allows automatic switch-on
according to the brightness. If
the parameter is On, then the
light controller switches on
automatically when the
brightness setpoint is greatly
undershot. We recommend
only using the parameter in
connection with the parameter
"Switch-off on brightness
overshoot".
Note: This parameter is not
yet active, as a light controller
has not yet been
implemented. 

Minimum brightness

1...67 %
Basic setting: 5 %

Specifies the minimum
settable brightness.
Note: If parameters or scene
values are set to a level lower
than the minimum brightness,
then the system will dim to
minimum brightness.

Maximum brightness

75...100 %
Basic setting: 100 %

Specifies the maximum
settable brightness.
Note: If parameters or scene
values are set to a level higher
than the maximum brightness,
then the system will dim to
maximum brightness.

Hotel function

On, Off
Basic setting: Off

If the hotel function is
activated, the system will dim
to 20 % brightness when a
switch-off command is made.
Switch-off is only possible with
a forced position command.
Note: If the minimum
brightness is set to greater
than 20 %, then the system
dims to the set minimum
brightness when the hotel
function is activated. 

Operating hours

0...65535
Basic setting: Current value

The time is counted during
which the load is physically
switched on (relay contact
closed).
This parameter can be reset to
"0", for example after
exchanging the load.
The Reset button is used to
reset the counter to "0". The
device must be programmed
to apply the change.

Information window

In the Information window, the load can be controlled and the information about the device can
be displays.

Display value

Explanations

10/11

82581013
J:0082581013

13.03.2014

eNet

Radio push-button controller 1-10 V

Summary of Contents for FM ST 50 UP

Page 1: ... part of the product and must remain with the end customer 2 Device components Figure 1 Device components 1 Operating mode switch 2 Button Prog 3 Status LED 4 Measuring points for voltage measurement terminals rear mounted 3 Function System information This device is a part of the eNet system High transmission reliability at a radio frequency of 868 MHz is achieved by the transmission behaviour an...

Page 2: ...d signalling could vary from what is described here i The parameter list is in the Internet in the documentation for this device Supplementary functions with eNet server Update of the device software Repeater function Reading of error memory Response after mains voltage return The response after mains voltage return can be configured with the eNet server Default setting Off 4 Operation Operation w...

Page 3: ...ous voltages to the device or load couple the miniature circuit breakers or label them with a warning to ensure disconnection is guaranteed o Insert the actuator in the appliance box in such a way that the Prog button 2 and status LED 3 are visible Figure 3 Operating mode switch Position Description PC Operating mode parameter set with eNet server G 1 10 V operation min Setting of the minimum brig...

Page 4: ...r The actuator and radio transmitter exit the programming mode automatically i If the status LED of the control unit flashes 3 times at 1 second intervals for approx 5 seconds then the programming operation was not successful All the memory locations in the actuator or radio transmitter are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as ...

Page 5: ...onger than 4 seconds The light switches off briefly and then switches on again to the new switch on brightness Switch on brightness is saved i Alternatively the switch on brightness can be saved with a radio transmitter e g wall transmitter 6 Appendix The icon confirms the conformity of the product to the relevant guidelines 6 1 Technical data Rated voltage AC 230 V Mains frequency 50 60 Hz Standb...

Page 6: ...ory setting Operating mode Normal operation Continuous on Continuous off Basic setting Normal Operation Normal operation The output can be operated with radio transmitters and the Prog button Continuous on The output switches to continuously On All operations of radio transmitters and the Prog button are ignored Continuous off The output switches to continuously Off All operations of radio transmi...

Page 7: ...as not yet been switched off due to the delay when a switch on command comes then the load will remain on Note The set time apply to operation using radio transmitters The device is switched immediately when the Prog button is pressed Dim up ramp 0 s 24 h Basic setting 0 s Time between switch on and reaching switch on brightness The light is switched on at minimum brightness and then dimmed to the...

Page 8: ...e Prog button is pressed Behaviour after the end of the disabling function On Off no change Last value Basic setting No change Behaviour of the output when a block is removed Behaviour on voltage return On Off Last value Configured brightness Basic setting Off Defines the behaviour of the output after voltage return Brightness on voltage return 0 100 Basic setting 100 Brightness value set by the o...

Page 9: ...is the highest priority and 4 the lowest 0 means no priority Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the priority for recalling and removing a scene of type Wind alarm for the channel Priority sun protection 0 4 Basic setting 0 Specifies the priority fo...

Page 10: ... level higher than the maximum brightness then the system will dim to maximum brightness Hotel function On Off Basic setting Off If the hotel function is activated the system will dim to 20 brightness when a switch off command is made Switch off is only possible with a forced position command Note If the minimum brightness is set to greater than 20 then the system dims to the set minimum brightnes...

Page 11: ...t polarity Cause 2 1 10 V control cables have short circuited Eliminate short circuit Lamps switch to maximum brightness No dimming is possible Cause 1 10 V control cables are interrupted or not connected Connect the control cables correctly 6 4 Accessories Installation box Art No FM EBG eNet server Art No ENET SERVER 6 5 Warranty We reserve the right to make technical and formal changes to the pr...

Reviews: