3.
Safety Instructions
3.1
Warnings for Unpacking, Handling, Assembly, Processing & Storage
Contusions
The sliders of linear motors contain neodynium magnets and have a very
strong magnetic force.
Careless handling could cause fingers or skin to become caught between
sliders and iron parts. This may lead to contusions, bruises, and bone
fractures. Protective gloves should be worn, when handling sliders.
Pacemakers / Defibrillators
When approaching strong magnetic fields, pacemakers or other devices,
may switch into test mode and will not function properly. As a wearer of such
a device, you should always keep the following minimum distances between
the devices and the sliders:
- 250 mm (10'') for slider diameters 27 mm and 28 mm (PL01-27 / 28)
- 150 mm (6'') for slider diameters 19 mm and 20 mm (PL01-19 / 20)
- 100 mm (4'') for slider diameter 12 mm (PL01-12)
Warn other persons, who wear these devices, to avoid getting too close to
sliders.
Magnetic Fields
Magnets integrated into the linear motor sliders produce a strong magnetic
field. They could damage TV's, laptops, computer hard drives, credit and
ATM cards, data storage media, mechanical watches, hearing aids, and
speakers.
Keep magnets away from devices and objects that could be damaged by
strong magnetic fields.
Please keep a minimum distance of 250 mm (10'') from the above mentioned
objects.
Flammability
The drilling dust can easily ignite while processing the magnets. Processing
the slider and the contained magnets is not permitted.