2.
Intended Use
2.1
Use of Linear Motor Modules
The linear motor modules are high-dynamic actuators. According to
European law 2006/42/EG the actuators are partly completed machines,
which are further installed into machines. They are used in machines for
industrial automation, handling and assembly technologies, packaging, as
well as testing technologies.
2.2
Assembly of Partly Completed Machines into Machines
In order to assemble the partly completed machines properly and without
compromising the safety and health of people, the following conditions must
be met:
- The installation of machines may only be carried out by qualified personnel.
- This document must be read and understood completely before installation.
- All warnings in this document must be observed.
A risk assessment for the complete machine must be carried out!
2.3
Operating Conditions
Conditions
- environmental temperature with nat. cooling 0°C to 40°C
- motor temperature -10°C to +80°C for std. linear motors
- motor temperature -10°C to +110°C for HP linear motors
(marked with HP).
- triggering of winding temperature control > 90°C for std. linear motors
- triggering of winding temperature control > 120°C for HP linear motors
- relative humidity
≤
60 % not condensing
- storage temperature -15°C to +70°C
The storage room must be dry, free of dust and frost and must be protected
from shock. The linear module must be protected from extreme weather
conditions. The storage room air may not contain any aggressive gases. The
maximum installation height is 4.000 m above sea level (MASL). When
installing above 1.000 m MASL, with identical motor power, a derating of
1 °C per 100 m is to be expected for air cooling.
The operating voltage of the linear motor stators
≤
72 VDC.