6
6190900 (Rev B)
87R-4P Compressor System User Guide
© 2017, JUN-AIR
We reserve the right to make any alterations which may be due to any technical improvements
Printed in the USA
Specifications
NO DRYER
100V
115V
230V
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
Model Numbers
1770018
1770008
1770009 (NA)
1770010 (EU/UK)
Continuous System
Output Flow @ 4 bar (58 psi)
46 SLPM
[1.6 SCFM]
51 SLPM
[1.8 SCFM]
46 SLPM
[1.6 SCFM]
51 SLPM
[1.8 SCFM]
46 SLPM
[1.6 SCFM]
51 SLPM
[1.8 SCFM]
Continuous System
Output Flow @ 8 bar (116 psi)
27 SLPM
[1.0 SCFM]
31 SLPM
[1.1 SCFM]
27 SLPM
[1.0 SCFM]
31 SLPM
[1.1 SCFM]
27 SLPM
[1.0 SCFM]
31 SLPM
[1.1 SCFM]
Cut-in Pressure
1
6 bar [87 psi]
Cut-out Pressure
1
8 bar [116 psi]
Maximum Operational Pressure
8 bar [116 psi]
Dew Point Suppression
2
N/A
Air Filtration
5
µ
m
Safety Relief Valve Pressure
9.3 bar (135 psi)
High Temperature Indication
≥
60 °C [140 °F] in compressor chamber
Air Connections
1/4 in BSPP
Current, A
5.0
5.8
4.8
5.3
2.6
2.9
Power Consumption, W
450
550
500
600
550
650
Fuse Specifications
12.5 A, 250 Vac, time delay
Sound Level, dB(A)
46
48
46
48
46
48
Operating Ambient Conditions
10 °C to 40 °C [50 °F to 104 °F]
10 - 95% RH*
Storage Ambient Conditions
-28 °C to 65 °C [-18 °F to 149 °F]
10 - 95% RH*
Barometric pressure >372 mm-Hg [14.7 in-Hg]
System Dimensions
W x H x D
406 mm x 495 mm x 439 mm
[16 in W x 19.5 in D x 17.3 in H]
System Weight
29.5 kg [65 lb]
Shipping Weight
35.0 kg [77 lb]
Regulatory Certifications
UL 1450 / CSA 22.2 / CE
1
The compressor switches on and off at the cut-in and cut-out pressures, respectively. The cut-in and cut-out pressures are adjustable.
2
Membrane dryer specifications are available upon request.
* Avoid conditions that promote condensation on the equipment.