87R-4P Compressor System User Guide
6190900 (Rev B)
INSTALLATION AND OPERATION
Intended Use
To provide compressed air for use with industrial or labora-
tory devices as a primary or back-up air source.
JUN-AIR compressor systems meet or exceed the most
current and highest safety standards, which are:
• UL1450, 4th edition
• CSA C22.2 68
• ISO 9001:2008
• Ingress protection: IP50
• 2006 / 42 / EC Directive
• RoHS compliant
To ensure the safety potential of this equipment is
achieved, please:
Make sure your equipment is installed according to the
instructions provided in this manual and make sure the
installation checklist is completed prior to starting the
equipment.
DANGER
The equipment is not suitable for use in the presence
of a flammable anesthetic mixture or with oxygen or
nitrous oxide.
DO NOT OPERATE THE EQUIPMENT IF
THESE CONDITIONS EXIST.
Transportation and Storage Conditions
• Temperature: -28 °C (-18 °F) to 65 °C (149 °F)
• Relative humidity: 10% to 95%
• Minimum barometric pressure: 372 mm•Hg
(14.7 in•Hg)
• Keep the system dry at all times.
• Do not stack units during shipment, installation, or us-
age.
Equipment Alert: Refer servicing to an authorized
service representative.
Unpacking
1. Cut the banding strap from the carton and remove the
lid and cardboard inserts.
2. Visually inspect the entire system for shipping damage
and verify that the following accessories have been
included: two (2) locking casters, two (2) non-locking
casters, four (4) vibration-isolation feet, four (4) studs,
four (4) washers, and one (1) power cable.
a. If the contents were damaged during shipping,
contact the freight carrier to file a claim.
b. If parts are missing, contact the supplier.
3. Use caution when removing the system from the
remaining packaging. Retain the packaging material for
future use, if necessary.
4. Install the casters or rubber mounting feet.
Before You Install...
Equipment Alert: Compressors are oil-less and
require NO lubrication.
Equipment Alert: The system must be installed in a
temperature-controlled and/or ventilated room to
ensure operational ambient temperature of 50 °F to
104 °F [10 °C to 40 °C]. A 12-inch clearance is required
on each side and top of unit to allow air flow.
Failure to do so could cause premature loss of
system performance and void warranty.
Personal Safety
DANGER
Risk of fire or explosion when using flammable substances.
Do not operate the system in an area containing combustible
gases or anesthetic mixtures.
CAUTION
Never leave children unattended near the system when in use.
WARNING
Property damage and/or personal injury may result
if directions are not followed or if the manufacturer’s
replacement parts/accessories are not used.
WARNING
Only connect equipment suitable for the listed maximum
pressure of the system.