33
9 Startup
9.6
On-site calibration
9.6.1
Display and operation
Display and operation
1. Normal state
(1) Green LED (1) is permanently lit
(2) Red LED (2) off
(3) Yellow LED (3) is lit depending on state
(4) Push-button (4) not pressed
Setting flow.
Teach-In function
Set switching point for all liquids.
High-level function
For flow velocities > 150 cm/s
or for variant 99 or DN > 50, high-level should be performed
for water.
High-level and
low-level function
For other liquids (except water)
a high-level and low-level calibration should be performed.
On
Error
O1
(2)
(4)
(1)
(3)