6 Installation
16
Avoid mechanical strain
Flow direction
Alignment of the housing for electronic components
Ensure that the center lines of
both ends of the pipes align be-
fore installing in the pipe (3).
Align the ends of the pipes parallel
and at an angle to one another.
Adhere to the insertion length L of
the device.
Installation accessories are avail-
able from the manufacturer.
Each mounting set contains two
union ends (1) and two union nuts
(2). Select the correct set for the
nominal width and pipe material in
question.
For the table of dimensions for the
mounting sets, please see:
Nominal width
Insertion length L [mm]
DN 15
160
DN 20
165
DN 25
175
DN 32
185
A
A
L
(1)
(2)
(3)
The positive flow direction (
) is
shown on the transducer covers
on both sides of the device and
must be observed during installa-
tion, in accordance with the appli-
cation in question.
CAUTION!
Protect the electronics
housing from being heated up by
hot media. Install the electronics
housing at medium tempera-
tures> 60 ° C (140 ° F) aligned 90
° to the side!
Front view
Side view
90°