4 Technical data
12
4.3
Electrical data
4.4
Mechanical features
4.4.1
Materials
4.4.2
Nominal pressure
4.4.3
Pressure loss diagram
Created under reference conditions
"Reference conditions", Page 10.
Voltage supply
DC 18 to 30 V SELV, PELV, Class 2
Current consumption
50 mA, with digital output 300 mA
Power consumption
≤ 10 W
Protection rating
DIN EN 61140, Class III (protective low voltage )
Electrical safety
The device must be equipped with an electrical circuit that meets the require-
ments of DIN EN 61010-1 with regard to "Limited-energy circuits".
Housing
PA66-GF25
Components in contact with the
medium
Meter run
PPSU
Transducer
PEEK
Seals
Process connection, transduc-
er
EPDM or FKM (optionally)
Approvals
Components in contact with the
medium
Drinking water certified materials (when using EPDM seals)
Nominal pressure levels
PN 16
X = Flow rate
max
(%)
Y = Pressure loss (mbar)
0
50
100
150
200
250
0
5
10
15
20
25
30
40
45
50
X
Y
mbar
35
%
DN 15
DN 25
DN 20
DN 15 low
DN 32
Summary of Contents for 406050