− 61 −
. . . Item that is not displayed due to other setting state.
No.
Item
Setting range
/
Edit unit
Initial value
Stacker timer 3
Motion time of material sweeping bar is set.
*
It is possible to set only when
clamp bar stacker opton s
used.
0.00 to
9.99
/
0.01 sec.
0.70 sec.
Stacker timer 4
Time to advance timing to release the sewing product by lifting clamp
foot is set.
When clampng a short sewng product, the amount to drop by tare s
adjusted.
*
It is possible to set only when
clamp bar stacker opton s
used.
0.00 to
9.99
/
0.01 sec.
0.00 sec.
Sewing speed under the high-speed mode
Number of revolutions of lockstitch section is set.
*
It is possible to set only when
sewng speed settng selec
-
ton s set to memory swtch.
1000 to
3000
/
100
st/mn
2500st/mn
Sewing speed under the low-speed mode
Number of revolutions of condensation and back tack sewing sections
s set.
*
It is limited by
sewing speed under the high-speed mode.
*
It is possible to set only when
sewng speed settng selec
-
ton s set to memory swtch.
*
In case of back tack sewing, the upper limit of number of revolu-
tions of the actual low speed is limited to 1,500 sti/min.
1000 to
2500
/
100
st/mn
1500st/mn
Soft start, first stitch
Number of revolutions of first stitch at sewing start is limited.
500 to
2500
/
100
st/mn
500st/mn
Soft start, second stitch
Number of revolutions of second stitch at sewing start is limited.
500 to
2500
/
100
st/mn
700st/mn
Soft start, third stitch
Number of revolutions of third stitch at sewing start is limited.
500 to
2500
/
100
st/mn
1000st/mn
Return speed of clamp foot
Return speed of clamp foot is set.
3 to 9
/
1
7