No.
Item
Setting range
40
Selection of number of invalid stitches at the
0 to 15 stitches
1
8
start of sewing of thread breakage detection
41
Selection of number of invalid stitches during
0 to 15 stitches
1
3
sewing of thread breakage detection
(At the time of control by motor)
0: Solid presser
1: Solid presser 2-step
stroke (Lowering again
with presser switch)
2: Solid presser 2-step
stroke (Down to the
start with
start switch)
3: Solid presser 2-step
stroke (Intermediate
→
down to bottom
→
going up with presser
SW)
4 to 99: Solid presser
(At the time of control
Feeding frame control
by air)
42
Procedure setting for feeding frame
0: Solid presser
1
0
1
0
8
2
operation with pedal operation under
1: Right/left separated
normal conditions
presser (Without
priority of right/left)
2: Right/left separated
presser (In the order
of right to left)
3: Right/left separated
presser (In the order
of left to right)
4 to 7: Special type (*1)
8: Solid presser
9: Solid presser 2-step
stroke
10: Right/left separated
presser 2-step stroke
(Without right/left
separation)
11: Right/left separated
presser 2-step stroke
(Order of right to left)
12: Right/left separated
presser 2-step stroke
(Order of left to right)
13 to 99: Solid presser
*1 : This is an option.
Initial value
SS/HS
SL/HL
SS/HS
SL/HL
SL/HL
1306
1306
1510
1510
2210
SL/HL
1306
FU
– 72 –
Smallest
c h a n g e -
able unit
Summary of Contents for AMS-210EN Series
Page 8: ...MEMO ...
Page 11: ... 4 MEMO ...
Page 232: ... 225 MEMO ...
Page 239: ... 7 MAIN PANEL board circuit diagram 232 PANEL BOARD MAIN BOARD ...
Page 248: ...MEMO 241 ...