3) SDC board
The power supply is generated and error check is carried out. Main shaft control is effected, receiving the commands from the MAIN board.
F1: 5A
Time lag fuse
For +85V
F2: 3.15A
Time lag fuse
For +33V
F3: 2A
Fast-blow type fuse
For +24V
CN10: 24V for the FAN
CN18: For IPM temperature sensor
CN13: For momentary interruption detection
←
FLT board
LED1: For operationa and error check
CN14: For Main shaft encoder
→
Main shaft motor
DIPSW 1-1: For testing - off
1-2: For testing - off
1-3: For testing - off
1-4: Penetration force - off
DIPSW 2-1: For weiting - off
2-2: For mode setting - off
2-3: For mode setting - off
2-4: For mode setting - off
CN15: For Main communication
→
Main board
CN16: For Main shaft motot power
→
Main shaft motor
CN17: For power supply
←
FLT board
LED2: For power
supply check
F5: 4A
Fuse fixed to the board
For +33V source primary
F4: 4A
Fuse fixed to the board
For +85V source primary
CN11: Power connector
→
Main board
+5V, +12V, +24V, +33V, +85V