![background image](http://html.mh-extra.com/html/juki/ams-210en-series/ams-210en-series_engineers-manual_2029613015.webp)
1. For mounting the main shaft motor with the coupling,
(1) Tighten 4 set screws
that securing the motor, and tighten 2 set screws
on the main shaft side of the
coupling
.
(2) The cords
of the main shaft motor
should be positioned in the lateral direction.
2. For connecting the coupling to the main shaft motor,
(1) Provide a clearance of 0.7 mm between the coupling
and main shaft motor
.
(2) Apply No. 1 set screw
of the coupling
to the flat section
of the main shaft motor
, the main
shaft
and secure it.
3. For engaging the coupling,
(1) Position the set screw
(No. 1 set screw) on the main shaft motor side between 2 set screws
on the
main shaft side, and engage the coupling.
– 8 –
Procedures of assembling