– 134 –
(10) Information screen at the maintenance personnel level
1. Error history
(1) To display the information screen at the mainte-
nance personnel level:
Hold down the information key, (A) for approx. 3
seconds in the switch sheet section on the data in-
put screen to call up the information screen at the
maintenance personnel level. On the information
screen at the maintenance personnel level, the color
of PICT at the upper left changes from blue to or-
ange, and there are 5 buttons.
(2) To call up the error history screen:
Press the error history button, (B) on the infor-
mation screen to call up the error history screen.
The error history screen shows the error history of
your sewing machine.
C: Chronological recording number
D: Error code
E: Cumulative energizing time during error (hour)
Pressing the cancel button, (G) closes the error
history screen and calls up the information screen.
(3) To display details:
For detailed information about errors, press the er-
ror button, (F) that you would like to
see to call up the error detail screen.
PICT (H) in response to error codes appears on the
error detail screen.
→
Refer to the “11. ERROR CODE LIST”.
D
C
G
E
F
B
A
H