(Very) Advanced Settings!
There are 8 settings in the
Advanced Settings
interface. None of these should need changing
when the unit arrives and should only be altered by someone who fully understands their
purpose. They are:
Battery Power Bar (
VOL
), Power Assistance Levels and Ratio (
PAS
), Over- Current Protection
(
CUR
), Power Assistance Sensor Direction (
RUN
), Speed Sensor Sensitivity (
SCN
) and Magnet
Number (
N
) and Sensor Number (
SPS
), Throttle Function (
HL
), System (
DLY
) and Power-on
Password Settings (
P2
).
To access these advanced settings hold both
UP
and
DOWN
for more than 2 seconds to enter
general settings, and then hold both
UP
and
DOWN
again to enter the Advanced Setting items
selection page.
Press
UP
or
DOWN
to choose a setting, and then press
MODE
to enter its individual value page.
Option Select Interface
Battery Power Bar Settings
You should never need to change these settings.
VOL indicates the voltage setting for each of the five battery level displays.
Each bar represents a voltage value. 5 voltage values must be entered one by one.
VOL
1
is the
first
bar voltage value, normally set to
31.5 volts
. Press UP or DOWN to increase or
reduce the value represented by the first bar. Press
MODE
to confirm and enter the second bar
value. After all 5 voltage values have been entered,
hold MODE
to confirm and return to previous
menu.
Battery Power Bar Settings