Power Assistance Sensor Settings
1.
Setting the
Direction
of the Power Assist Sensor (PAS)
PAS
refers to the power assist sensor settings. The first setting in this menu chooses the
direction of rotation for the pedal sensor disk. “
run-F
” means
clockwise
, while “
run-b
” means
anti-clockwise
. Press
UP
or
DOWN
to select
F or b
, and press
MODE
to confirm and enter the
setting. The default direction is “run-F” (When the pedals are turned forwards, the motor runs).
It can be useful to change this setting if the Sensor Disk has been mistakenly reversed.
Direction of PAS Sensor Settings
2.
Adjusting the
Sensitivity
of the PAS sensor
SCN
shows the setting for the sensitivity of the pedal sensor. The values that may be used are
from 2 (strongest) to 9 (weakest). The default value is 2 and this should pick up the signal from
the sensor perfectly, but if less sensitivity is preferred choose a higher number.
Press
UP
or
DOWN
to change the pedal sensor sensitivity value, and then press
MODE
to confirm
your choice.
The Sensitivity of PAS Settings
Once you have confirmed the SCN, pedal sensor sensitivity, you then need to confirm or change
the number of magnets (N) in the PAS sensor plate (the black disk behind the pedal chain wheel).
3.
Number of magnets
on PAS plate
N
refers to the number of magnets found on the PAS disk. Press
UP or DOWN
to select the
correct quantity corresponding to your PAS plate. The default value is 6 but you may need to
change this should you ever use a replacement plate.
Number of PAS Magnets