BEFORE YOU BEGIN

Inspect carton and product carefully and
thoroughly for defects or shipping
damage.

Turn off the main water supplies.

Use this product in accordance with all
the respective local regulations, codes
and safety practices.

Do not install this product in applications
were the ambient temperature is below
4 Celsius.

Do not install this product closer than 13
feet (4 m) of plumbing piping between
the filter outlet and the inlet of any water
heater. Water heaters can and will
transmit heat back through its respective
plumbing. Always ensure that this
product is installed so that the water
temperature never exceeds a maximum
of 30 °C (86° F) for all applications. If in 
doubt, always check with local plumbing
and building authorities prior to installa-
tion.

Do not install in applications where
exposed to direct sun radiation/ sun
light.

Do not expose this product to solvents or
cleaners containing alcohol or petroleum
products.

Do not install this product near acid or
acid fumes.

All plumbing MUST conform to local
codes.

All plumbing must be properly supported
with no stress to be put on product or
piping.

Summary of Contents for JPM

Page 1: ...structions as well as all safety information before installing and putting the unit into service These Instructions must always be issued to the owner user Installation and Operating Instructions JUDO...

Page 2: ...prevention The JUDO PROMI is suitable for use in COLD water applications only up to a water temperature of maximum 30 C 86 F and up to a water pressure of maximum 16 psi It filters out all coarse and...

Page 3: ...heater Water heaters can and will transmit heat back through its respective plumbing Always ensure that this product is installed so that the water temperature never exceeds a maximum of 30 C 86 F fo...

Page 4: ...4 JUDO PROMI...

Page 5: ...y available at the place in which the filter is installed and used This instruction manual is intended to make it easier to familiarize yourself with this filter The instruction manual contains import...

Page 6: ...can result for example in the following risks Failure of important functions and features of this product Danger to persons due to electrical and mechanical conditions Danger to property and the envi...

Page 7: ...ructions The manufacturer supplier should be consulted prior to any operation of the filter other than in the operational areas stated in these operating instructions The filter may only be operated i...

Page 8: ...of DIN 50930 6 Impact on the Drinking Water Quality 4 Installation 4 1 General ATTENTION see chapter Safety information and dangers due to non compliance The unit may only be installed by skilled per...

Page 9: ...ertical position 5 Non observance of this can cause uncon trolled leakage of backwashing water and can result in water damage 4 1 3 Mounting the built in rotary flanges Install using the supplied buil...

Page 10: ...ances e g wastewater pipe gradient number of pipe bends length of the waste water pipe etc The dimensioning must at least allow all the wastewater to be dis charged at the same time If it is not possi...

Page 11: ...Installation 4 2 1 Backwashing water discharge options JPM 1 JPM 1 2 Abb 4 Backwashing water discharge options min 10 l 200 mm 8 inch min 10 l 200 mm 8 inch 25 mm 1 inch 40 mm 1 5 inch 25 mm 1 inch 4...

Page 12: ...heel It uses an acoustic alarm as a reminder that every two months the filter needs to be back washed maximum backwash intervals Activation Lift the lid of the handwheel Insert the two batteries in th...

Page 13: ...reducer 6 The set outlet pressure can be read off on the outlet pressure gauge 7 Then the filtered water runs out of the domestic water station via the built in rotary flange 1 1 Built in rotary flan...

Page 14: ...rinsing valve Step 2 turn hand wheel 2 clockwise until stop point to close rinsing valve During a backwash the suction control arms create a reverse flow action at each nozzle piece resulting in a vac...

Page 15: ...to check batteries regu larly to ensure they have not been exhausted The beep is only considered an additional reminder for backwashing Independent of that the backwashing needs to be carried out eve...

Page 16: ...after replacement has been made 5 6 Stoppages ATTENTION see chapter Safety information and dangers due to non compliance If a filter has to be removed from the flange or unscrewed the chapter Intende...

Page 17: ...flushing valve Lack of water pressure Screen is blocked Carry out backwashing Leaks in the backwash protective filter Inform the fitter or nearest cus tomer service centre The filter cover must be rep...

Page 18: ...rval is restarted Used batteries are to be returned to a distributor or to one of the returning faci lities established to this purpose by the public recycling entities ATTENTION see chapter Safety in...

Page 19: ...filter The backwashing volumetric flow given ap plies to 2 4 psi mains pressure and for a completely opened flushing water valve Models Order no JPM 8170200 JPM 1 8170201 JPM 1 8170202 JPM 1 8150107 J...

Page 20: ...pipe centre E Depth to pipe centre F Connection dimension waste water Fig 6 Installing dimensions JPM 1 built in rotary flange horizontal piping built in rotary flange vertical piping Models A B C D...

Page 21: ...domestic water station Installation and operation instructions JPM 1 1 x built in rotary flange JQE 1 or 1 with bayonet type connection and screw connection 2 x batteries to be used in the Memory Ele...

Page 22: ...22 JUDO PROMI Spare Parts 10 Spare Parts 10 1 JPM 1...

Page 23: ...3 Type plate 1 1701915 10 Cylinder Screw M6x40 6 1650123 11 Flange ring 1 2010382 12 Filter housing 1 1120289 13 O ring 10x3 2 1120332 14 Carrier 1 2010146 15 Suction Pipe Gasket 1 1607410 16 Mouthpie...

Page 24: ...ometer seal 2 1200117 38 O ring 14 5x2 5 4 1200231 39 Pressure gauge tube 2 1120349 40 manometer 0 10 psi Subsequent Pressure 1 2170121 41 manometer 0 16 psi Primary Pressure 1 2170120 42 Hollow screw...

Page 25: ...JUDO PROMI 25 Spare Parts 10 2 JPM 1 2...

Page 26: ...15x3 2 1 1607420 10 O ring 28x2 5 1 1200027 11 Carrier 1 2020034 12 Mouthpiece Nozzle 2 1607104 13 Suction Pipe Gasket 1 1607113 14 Plate Screw C3 5x13 1 1607114 15 Complete Suction control Assembly...

Page 27: ...42x2 7 1 1200143 34 Protection cap 1 1440082 35 Profile flange seal 1 1200230 36 Cylinder Screw M8x140 4 1650376 37 Washer A 8 4 4 1607125 38 Hexagonal nut M8 4 1607117 Spare part set consisting of It...

Page 28: ...DO Waterbehandeling GmbH Filiaal Filiale BeNeLux Laerbeeklaan 72 A1 72 A1 Avenue du Laerbeek B 1090 Brussel Bruxelles Tel T l 32 0 24 60 12 88 Fax 32 0 24 61 18 85 e mail info benelux judo eu www judo...

Reviews: