JUDO i-soft
9
Installation
4.1.1 Requirements for the place of
installation
The room where the unit is installed must
be dry and frost-free!
Unauthorised persons must not have
access to the softener!
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
–
The ambient temperature must not
exceed 30 °C (86 °F)!
–
In order to be able to safely discharge
the wastewater (regeneration) in opera-
tion and in case of any defects that occur
in the system, precise compliance with
the details given in the “Installation”
chapter is necessary!
If the wastewater cannot be safely and
completely discharged, then this may
result in water damage to the house and
installations therein.
–
If no bypass valve (JQX) is installed,
there must be a shut-off valve upstream
of the softener! This enables the water
supply to the softener to be interrupted
during installation, servicing/mainte-
nance, repairs and in case of malfunc-
tions.
–
The unit can be installed in all standard
drinking water pipes.
–
It is not permitted to install the softener
upstream of the water meter!
4.1.2 Installation position
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
Always install the softener in a vertical posi-
tion (± 5°)!
Failure to observe this can impair its function.
4.1.3 Power supply
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
The mains voltage may not be interrupted
(e. g. by light switches). If the power supply
is interrupted during regeneration,
–
no regeneration takes place.
–
no alarm is given in case of faults.
–
water losses or even water damage can
occur.
4.1.4 Mounting the built-in rotary
flange
The built-in rotary flange is used as a
connecting element between the pipe and
the softener.
It is suitable for both horizontal and vertical
pipes.
The installation height depends on the pipe
layout. The minimum installation height from
the floor to the rotary flange is 52 cm (20.5
inch).
The built-in rotary flange must be
installed in flow direction which is
marked by a cast in arrow (see fig. 4).
Failure to comply with this means the
softener cannot work.
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
A power connection (230 V, 50 Hz),
which is permanently live, must be
available.
A splash proof socket is required for
the transformer, in accordance with
the legal regulations for wet rooms.