20
JUDO i-soft
Operation
5.3.1 Message “Verify salt level”
Usually, regeneration salt is filled up using
25 kg sacks. This amount of salt provides at
least 100 regenerations. After 100 regene-
rations, the display indicates:
After this message, fill up with 25 kg of
regeneration salt. Then press the <OK> key
briefly. This will reset the warning message.
If regeneration salt has already been filled
up before the display indicates it is neces-
sary to do so, the salt quantity regeneration
counter can be reset by pressing <OK>
together with key <1>. The display will then
show the following message:
After 5 seconds, the operating mode comes
up on the display.
5.3.2 Message in case of
insufficient salt
The salt concentration of the brine is
checked during each regeneration. If the salt
container is not topped up in time and the
brine concentration is too low, the display
indicates:
After this message, fill with 25 kg of regener-
ation salt. Then press the <OK> key briefly.
This will reset the warning message.
If salt is only filled up after the salt storage is
completely used up, the brine level might
increase temporarily. In this case, the
suction procedure may take longer.
Our recommendation: Broxo or Solvay
salt, or local equivalent, either in blocks, tab-
lets or in the form of coarse grains sized 7 -
15 mm.
ATTENTION
(see chapter “Safety information and dan-
gers due to non-compliance”)
If the regeneration salt is used up or is not
topped up in time, the water softener
switches to economy operation.
In this case, the brine that is still available is
primarily used for disinfecting the ion
exchanger resin and the softening action is
reduced.
This way, the water softener stays in a
thoroughly hygienic condition even for
weeks after the regeneration salt was indi-
cated as being insufficient.
5.4
Potential-free error message
In the following cases a collective error
message can be transferred through the
potential-free relay:
–
if there is an error message of the water
softener
–
in case of power failure
–
in case of insufficient salt
Verify
salt level
Salt reg. counter
reseted
Attention!
Salt deficit
This message might also come
up if the brining procedure cannot
be carried out properly during
regeneration e.g. if the waste
water hose has been installed too
high, if there is insufficient line
pressure or if the suction hose
has not been connected properly
to the salt/brine container.