WARRANTY 

JRI products carry a one year warranty and guarantee against defects in their components or workmanship. 
During this period if any product supplied by the Company proves on inspection to be defective, the Company will at its 
own option replace the same or refund to the Buyer the price of the product. 
In no circumstances will JRI' liability exceed the price of the product paid by the buyer or the cost of replacement. 
JRI shall not in any event be liable to the Buyer for any indirect or consequential loss or damage costs or expenses 
whatsoever which might arise out of or in connection with the supply of the product or its consequent use. 
Consequently, the products warrantee and guarantee specified above, does not cover damage caused by fair wear and 
tear, abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication or modification, or 
use with non-JRI' hardware/software. No warranty of fitness for a particular purpose is offered and the user assumes 
the entire risk of using the product. 
In line with our policy of continuous development, we reserve the right to amend our product specification without 
prior notice. 
 

VII.

 

MAINTENANCE CONTRACT 

How to optimize your radio frequency installation? 

RF measuring systems communicate by radio frequency. However, there may be several factors that can modify the 
radio ways already defined, such as moving from a building, adding walls, … Radio frequency requires thus a periodical 
follow up performed by specialists.   
That’s why JRI has created maintenance contracts. We bring you a global solution which makes your maintenance 
easier. This overall service offer includes maintenance and also metrological services, which ensure you that your 
system is fully performant. 

You won’t worry about your devices maintenance anymore 

With this maintenance contract you will benefit for a minimal period of 2 years from the following advantages:  

- material verification once or twice a year 
- warranty extension 
- telemaintenance 
- telephone assistance  
- material replacement on site or by return to our production unit 
- metrological certificates: verification of measurement accuracy 
- access to new software versions and updates 
- on-site intervention within 3 open days after problem identification by our experts 
 

VIII.

 

 

ENVIRONMENT PROTECTION 

JRI recommends to our customers to throw away their measuring and recording devices which are unserviceable 
and/or beyond repair in a way that is appropriate to environment protection. Insofar as the production of waste 
cannot be avoided, it is best to re-use them by proceeding with adapted recycling depending on the material used and 
considering the environment protection. 

RoHS Directive 

The ROHS European Directive rules and limits the presence of hazardous substances in electrical and electronic 
equipments (EEE).  
 
In the article 2, the scope of this Directive excludes "9. Monitoring and Control Instruments" and our products are part 
of this category.  
 
However, our company has decided to apply the whole dispositions of this Directive for all our new electronic devices 
which will comply to this 2002/95/CE Directive.

 

Summary of Contents for Spy RF ModeM Wifi

Page 1: ...USER MANUAL Spy RF ModeM Wifi 10392...

Page 2: ...mounting bracket 4 IV CHARACTERISTICS 5 V INSTALLATION OF THE SPY RF WIFI MODEM 5 1 Connecting to the mains 5 2 Setting up a connection with the WiFi Module 5 3 Checking the Network connection 8 4 Che...

Page 3: ...vice is powered by 9VDC 650mA from a 100 230 VAC power supply adaptor Comply with the security and utilisation regulations of electric power Use an electric installation complying with these regulatio...

Page 4: ...ns cold rooms etc Do not place the SPY RF devices in a horizontal position If you are still having problems you may find it helpful to use a SPYRF Relay repeater or to connect another SPY RF ModeM to...

Page 5: ...SSID Connect Authentication none i e open Encryption none Channel Auto 1 6 11 preferred DHCP server enabled This temporary open WiFi Network is necessary to set up the SPY RF WiFi ModeM and this throu...

Page 6: ...re that the WiFi ModeM finds the network refer to paragrah c Connecting to the mains paragraph Once the two devices have been connected to each other move on to paragrah d Checking of the network conn...

Page 7: ...t already exists the Modem will connect automatically click on Properties If it doesn t exist click on Add to create it In the Wireless Network Properties select 1 Network name SSID Connect or alterna...

Page 8: ...ear or if no DigiConnect Wi ME line appear you should Unplug the Modem then plug in again and click on Refresh once the connection has been established if it still doesn t appear change the name of th...

Page 9: ...9 The Login window will appear in your browser Enter Username root Password dbps then click Login The home page of the Digi Connect Wi ME configuration and Management will appear Click on Update Firm...

Page 10: ...y can be found on the CD in the POST and FIRMEWARE files respectively Update the POST first then the FIRMWARE To apply click on Update At last select Reboot Administration Menu Reboot 5 Configuration...

Page 11: ...IP address assignment Then click on Apply Nota you need to reboot the module if you want to change the IP address After reboot the le DIGI configurator Digi will become available when entering the new...

Page 12: ...isable the Open Connect network Installation of the Digi Connect Wi ME drivers This installation should be repeated for each SPY RF WiFi Modem used on the network Plug in the Modem Insert the installa...

Page 13: ...fields No Ports and starting com as they are Make sure that the default RealPort TCP value is 771 If not then modify it Deselect Encryption and Authentification Accept despite the warning message At...

Page 14: ...Wifi ModeM has not been detected by Sirius relaunch the com SIRIUS task If the SPY RF Wifi ModeM is still not connected restart the computer If the SPY RF Wifi ModeM is still not connected then go to...

Page 15: ...iodical follow up performed by specialists That s why JRI has created maintenance contracts We bring you a global solution which makes your maintenance easier This overall service offer includes maint...

Reviews: