5-66
5.8. Connecting the AP Local Management Tool
Open the cover of the AP-IFU.
Connect the AP local management tool terminal to the MNT port of the AP-IFU using the AP local
management cable as shown in Figure 5-21
Figure 5-21 Connection
:
Use a T25 torx driver to open the AP-IFU cover.
MNT port
AP Local management tool(PC)
AP Local management cable
・
When opening the AP-IFU cover, make sure that the four special screws are loosened
completely. Forcing to open the cover may damage it.
・
After you opened the AP-IFU cover, make sure to secure it using the stopper. Otherwise,
you may get hurt. To close the cover, be sure to return the stopper to the original position.
・
If it is difficult to tighten the four special screws of the AP-IFU cover, adjust the locations of
the screw holes (support the cover and align the top of the cover to that of the chassis)
and tighten the screws. Forced tightening of the screws may damage the cover and
screws.
・
When closing the cover, be careful not to nick cables.
Summary of Contents for NT337-XL2
Page 1: ...0 JRC FWA SYSTEM INSTRUCTION MANUAL Rev 3 4 24 SEP 2008...
Page 34: ...2 11 2 2 1 2 AP RFU Omni Antenna Mounting Bracket in mm Figure 2 3 Mounting Bracket...
Page 37: ...2 14 2 2 2 2 AP RFU Sectoral Horn Antenna Mounting Bracket in mm Figure 2 6 Mounting Bracket...
Page 38: ...2 15 2 2 3 AP IFU in mm Figure 2 7 External View of the AP IFU a...
Page 39: ...2 16 2 2 3 1 AP IFU Nameplate Nameplate a in mm Figure 2 8 Nameplate 1 Blank non RoHS R RoHS 1...
Page 40: ...2 17 2 2 4 WT in mm Figure 2 9 External View of the WT 60 a b c 61 190 190 d...
Page 43: ...2 20 2 2 5 WT External Antenna Figure 2 12 External View of the WT External Antenna...
Page 137: ...7 114 Figure 7 2 Configure the WT master Step1 Step4 Step3 Step2 Step5 Step6...
Page 187: ...11 164 JRC FWA SYSTEM Instruction Manual H 7YZCM0101B Rev 3 4 24 SEP 2008...