3-30
3.2.3. Operations and Indications
3.2.3.1. Indications
Figure 3-5 AP-IFU Operation and Indication Panel
Table 3-1 AP-IFU Indications
LED
State indication
a
POWER
Lit green: Power on
Extinguished: Power off
b
ETHER 1
Lit green: ETHER link established
Flashing green: ETHER signal sent or received
Extinguished: ETHER link down (See Table 3-3, 4)
c
ETHER 2
Lit green: ETHER link established
Flashing green: ETHER signal sent or received
Extinguished: ETHER link down (See Table 3-3, 5)
d
IFU STATE
Lit red: IFU alarm (See Table 3-3, 2)
Flashing green: Normal (CPU running)
Flashing orange: During initialization
e
RFU ALARM
Lit red: RFU alarm (Cause: RFU failure (See Table 3-3, 1) or
communication error between the IFU and RFU (See Table 3-3, 3))
Extinguished: RFU alarm cleared
f
ETHER1 AUTO
Lit green: AUTO (ETHER1 AUTO switch set to AUTO)
Extinguished: 100BASE full duplex
g
ETHER2 AUTO
Lit green: AUTO
Extinguished: 100BASE full duplex
h
RST
Unit reset switch
制御盤LED部拡大図
26G-2-AP-PWR
26G-2-AP-CNT
P
O
W
E
R
E
T
H
E
R
1
E
T
H
E
R
2
IF
U
S
T
A
T
E
R
F
U
A
L
A
R
M
AUTO
100
FULL
AUTO
100
FULL
ETHER1 AUTO ETHER2 AUTO
①
②
③
④
⑤
⑥
⑦
⑧
b
c
d
e
f
g
a
h
Summary of Contents for NT337-XL2
Page 1: ...0 JRC FWA SYSTEM INSTRUCTION MANUAL Rev 3 4 24 SEP 2008...
Page 34: ...2 11 2 2 1 2 AP RFU Omni Antenna Mounting Bracket in mm Figure 2 3 Mounting Bracket...
Page 37: ...2 14 2 2 2 2 AP RFU Sectoral Horn Antenna Mounting Bracket in mm Figure 2 6 Mounting Bracket...
Page 38: ...2 15 2 2 3 AP IFU in mm Figure 2 7 External View of the AP IFU a...
Page 39: ...2 16 2 2 3 1 AP IFU Nameplate Nameplate a in mm Figure 2 8 Nameplate 1 Blank non RoHS R RoHS 1...
Page 40: ...2 17 2 2 4 WT in mm Figure 2 9 External View of the WT 60 a b c 61 190 190 d...
Page 43: ...2 20 2 2 5 WT External Antenna Figure 2 12 External View of the WT External Antenna...
Page 137: ...7 114 Figure 7 2 Configure the WT master Step1 Step4 Step3 Step2 Step5 Step6...