JMA-9100/7100 Installation Manual > 2.INSTALLATION OF SCANNER UNIT > 2.1 EQUIPMENT CABLE
2
-
1
2
2.1
EQUIPMENT CABLE
2.1.1
CFQ-6912-**
This is a 19-core shielded composite cable.
The cable length is indicated in the asterisks ** area in the model name, and the
available cable lengths are 5, 10, 20, 30, 40, 50, and 65 meters.
This cable is used to connect an NKE-2103 type scanner or an NKE-2254 type
scanner to the display unit.
Fig 2-1:
Cross-sectional drawing of CFQ-6912
maximum diameter 14.5mm
Table2-1
:
CFQ-6912 wire
Core(NO)
AWG
No. of Wire /
φ
Color
Remarks
1
AWG24
7/0.2T
Black1
Coaxial
2
AWG24
7/0.2T
Black2
Shield
3
AWG24
7/0.2T
Green
4
AWG24
7/0.2T
Yellow
5
AWG24
7/0.2T
White
6
AWG22
17/0.16T
Black
7
AWG22
17/0.16T
Orange
8
AWG16
50/0.18T
Blue
9
AWG16
50/0.18T
Gray
10
AWG16
50/0.18T
Purple
11
AWG16
50/0.18T
Brown
12
AWG16
50/0.18T
White
13
AWG16
50/0.18T
Orange
14
AWG16
50/0.18T
Red
15
AWG16
50/0.18T
Green
16
AWG16
50/0.18T
Yellow
17
AWG16
50/0.18T
Black
18
AWG16
50/0.18T
Sky
19
AWG16
50/0.18T
Pink
Summary of Contents for JMA-7122-6XA
Page 2: ......
Page 8: ......
Page 22: ......
Page 24: ......
Page 42: ...1 18 JMA 9100 7100 Installation Manual 1 EQUIPMENT COMPOSITION 1 2 LIST OF CIRCUITS ...
Page 80: ...2 36 JMA 9100 7100 Installation Manual 2 INSTALLATION OF SCANNER UNIT 2 4 PRECAUTIONS ...
Page 128: ......
Page 222: ......
Page 224: ...6 2 JMA 9100 7100 Installation Manual 6 Appendix 6 1 EXTERIOR DRAWING Fig 6 1 NKE 1139 ...
Page 315: ......