2
-
2
JMA-9100/7100 Installation Manual > 2.INSTALLATION OF SCANNER UNIT > 2.1 EQUIPMENT CABLE
2.1.2
2695110056
This is a 14-core shielded composite cable.
This cable is used to connect an NKE-1125 type scanner or an NKE-1130 type
scanner, and an NTG-3225 type transmitter-receiver or a NTG-3230 type
transmitter-receiver to the display unit.
Fig 2-2:
Cross-sectional drawing of 2695110056
maximum diameter 23.0mm
Table2-2
:
2695110056 wire
Core (No.) C r o s s
Section
(m2)
No. of wire /
φ
Color
Remarks
1
0.5
19 / 0.18
Black 1
Coaxial Cable
2
0.5
19 / 0.18
Black 2
Coaxial Cable
3
0.5
19 / 0.18
Black 3
Coaxial Cable
4
0.5
19 / 0.18
Black 4
Coaxial Cable
5
5.5
35 / 0.45
Yellow
6
5.5
35 / 0.45
Green
7
5.5
35 / 0.45
Brown
8
0.3
12 / 0.18
White
Twisted pair cable with
Shield sheath white
9
0.3
12 / 0.18
Orange
10
2
37 / 0.26
Red
11
2
37 / 0.26
Blue
12
1.25
50 / 0.18
Black
13
1.25
50 / 0.18
Purple
14
0.5
1 / 0.18
Gray
Shield wire
Summary of Contents for JMA-7122-6XA
Page 2: ......
Page 8: ......
Page 22: ......
Page 24: ......
Page 42: ...1 18 JMA 9100 7100 Installation Manual 1 EQUIPMENT COMPOSITION 1 2 LIST OF CIRCUITS ...
Page 80: ...2 36 JMA 9100 7100 Installation Manual 2 INSTALLATION OF SCANNER UNIT 2 4 PRECAUTIONS ...
Page 128: ......
Page 222: ......
Page 224: ...6 2 JMA 9100 7100 Installation Manual 6 Appendix 6 1 EXTERIOR DRAWING Fig 6 1 NKE 1139 ...
Page 315: ......