2
-
26
JMA-9100/7100 Installation Manual > 2.INSTALLATION OF SCANNER UNIT > 2.4 PRECAUTIONS
2.4
PRECAUTIONS
2.4.1
Installation of scanner unit
1)
Precautions for transporting and storing the scanner
•
An scanner is a heavy load. Be very careful about handling it.
•
Do not allow the scanner fall on its side while it is stored or being installed.
•
Do not apply rope to the scanner in the way that squeezes or deforms the radiating
section.
•
When hoisting the scanner by a crane, do not hoist it by attaching a belt or a rope only
to the scanner's radiating section as shown in Fig 2-11.
•
For the S-band, attach a rope to the hoisting eyebolts attached to the scanner's chassis,
and then hoist the scanner (Fig 2-12). If a belt or a rope is attached to the scanner's
support section located at the bottom of the radiating section, a load is imposed to the
joint between the radiating section and the chassis.
•
For the X-band, wrap a cloth around the scanner's support section located at the bottom
of the radiating section, and then attach a belt or rope to it to hoist the scanner (Fig 2-
13).
Fig 2-11:
Improper way to hoist
Fig 2-12:
S-band
Fig 2-13:
X-band
Attach a rope to the
hoisting eyebolts
Summary of Contents for JMA-7122-6XA
Page 2: ......
Page 8: ......
Page 22: ......
Page 24: ......
Page 42: ...1 18 JMA 9100 7100 Installation Manual 1 EQUIPMENT COMPOSITION 1 2 LIST OF CIRCUITS ...
Page 80: ...2 36 JMA 9100 7100 Installation Manual 2 INSTALLATION OF SCANNER UNIT 2 4 PRECAUTIONS ...
Page 128: ......
Page 222: ......
Page 224: ...6 2 JMA 9100 7100 Installation Manual 6 Appendix 6 1 EXTERIOR DRAWING Fig 6 1 NKE 1139 ...
Page 315: ......