8
─
67
Adjustment of NSK Unit to GYRO Compass and Log
The NSK Unit of the radar equipment is designed to be compatible with almost all types of gyro compass by
switch operation (For the step motor type, 24 VDC to 100 VDC, and for the synchro-motor type, the primary
excitation voltage is 50 VAC to 115 VAC).
Before power-on operation, the switches S1, S2, S5 and jumper JP1 on the NSK Unit (NCT-4106) shall be set
to the type of gyro compass in use in accordance with the procedures as described below. The gyro select
switch on the NSK Unit is set to the gyration ratio of 360X and to be compatible with the synchro type before
delivery from factory.
Check the type of the gyro compass used in own ship and make settings in the procedures below.
(1) Set the switches of the NSK Unit (NCT-4106) before turning on the radar equipment.
•
S1: Set it to [OFF].
•
S2: There are two types of gyro compasses: a compass of one type outputs a step signal, and the other
outputs a synchro signal. Make sure of the type of gyro compass used with the own ship before
setting S2.
[SYNC]....................................... Synchro signal
[STEP] ........................................ Step signal
•
S5: Set S5 depending on the type of the gyro compass currently in use, according to the S5 setting
table.
S5-1: ................................. Set this switch assembly according to the particular type of gyro.
[OFF] .......................................... Synchro signal
[ON]............................................ Step signal
S5-2, -3............................... Gyration ratio
360X
180X
90X
36X
S5-2 OFF OFF
ON ON
S5-3 OFF ON
OFF ON
S5-4 .................................... Gyration direction
[OFF] .......................................... Normal (clockwise)
[ON]............................................ Reverse (counterclockwise)
S5-5 .................................... Log type-1
[OFF] .......................................... Pulse signal
[ON]............................................ Synchro signal
S5-6 .................................... Not used
Summary of Contents for JMA-5206
Page 2: ......
Page 28: ...xxii ...
Page 30: ...xxiv ...
Page 31: ... xxv Environ mental Protection ENVIRONMENTAL PROTECTION ...
Page 32: ...xxvi ...
Page 39: ...1 6 1 4 EXTERIOR DRAWINGS y 1 Fig 1 1 Exterior Drawing of Scanner Unit Type NKE 2062 HS ...
Page 40: ...1 7 Fig 1 2 Exterior Drawing of Scanner Unit Type NKE 2102 4 ...
Page 41: ...1 8 1 4 EXTERIOR DRAWINGS y 1 Fig 1 3 Exterior Drawing of Scanner Unit Type NKE 2102 6 ...
Page 42: ...1 9 Fig 1 4 Exterior Drawing of Scanner Unit Type NKE 2252 7 ...
Page 43: ...1 10 1 4 EXTERIOR DRAWINGS y 1 Fig 1 5 Exterior Drawing of Scanner Unit Type NKE 2252 9 ...
Page 44: ...1 11 Fig 1 6 Exterior Drawing of Monitor Unit Type NWZ 164 ...
Page 45: ...1 12 1 4 EXTERIOR DRAWINGS y 1 Fig 1 7 Exterior Drawing of Processor Unit Type NDC 1340 ...
Page 46: ...1 13 Fig 1 8 Exterior Drawing of Keyboard Unit Type NCE 7699 ...
Page 47: ...1 14 1 4 EXTERIOR DRAWINGS y 1 Fig 1 9 Exterior Drawing of NSK Unit Type NCT 4106 ...
Page 52: ...1 19 ...
Page 68: ...2 15 ...
Page 218: ...4 7 ...
Page 280: ...5 61 ...
Page 292: ...6 11 ...
Page 345: ...8 44 8 5 Adjustments yyyy yyyy 8 Exit 1 Press RADAR MENU key The Main Menu will reappear ...
Page 402: ...8 101 ...
Page 403: ...SECTION 9 AFTER SALES SERVICE ...
Page 406: ...9 3 ...
Page 430: ...11 19 ...
Page 438: ...Figure 7 Key board unit NCE 7699 Inter connection Diagram ...
Page 439: ...APPENDIX Figure 8 JMA 5200 On screen controls ...
Page 456: ......
Page 458: ...1 ...
Page 460: ...3 ...
Page 461: ......