51 | Operation
2.3.7.1 Select Sensor for F.U. (Follow Up)
Select a sensor for Follow Up in the position screen (Figure 39: Position Screen (F.U.) on page 50). If the sensor was
in use as normal positioning sensor then first deselect it, where the Laser sensor can be selected to be used for Follow
Up.
Only one sensor can be used for Follow up at a time. To change to another sensor, first the selected sensor has to be
deselected, which sets the system from Follow mode back to Auto position mode.
Figure 40: Follow Up (F.U.)
2.3.7.2 Set system to Auto Position Follow Mode
After selecting a sensor for Follow up in the Position screen (Figure 39: Position Screen (F.U.) on page 50), the
system can be changed from Auto Position mode to Auto Position Follow mode in the FOLLOW screen (Figure 40:
Follow Up (F.U.) on page 51).
Change to follow mode by clicking the FOLLOW button in the Follow screen. A fixed offset distance from the sensor can
also be entered here by double clicking the Target Offset inputs.
Summary of Contents for Alphatron Marine AlphaDynaPos
Page 1: ...AlphaDynaPos Ship Automation and Navigation system Operation Manual www jrc am ...
Page 5: ...5 Contents 4 2 Appendix B Checklist for Taking DP system into Operation 85 ...
Page 13: ...13 Introduction III 3 System Overview DP2 Figure 2 system Overview DP2 ...
Page 14: ...14 Introduction III 4 Sensor Overview Figure 3 Sensor Overview ...