![JPS RTU-292C Installation And Operation Manual Download Page 82](http://html1.mh-extra.com/html/jps/rtu-292c/rtu-292c_installation-and-operation-manual_2028049082.webp)
RTU-292C Operations Manual
5-4
5.5.2.2
Alternate Hybrid Test Procedure
This alternate test procedure uses a more easily obtainable audio signal generator in place of the
noise generator. While this procedure cannot give a complete picture of the unit’s performance
in actual use, it will allow a determination of whether or not the RTU-292C is operating properly.
1. Disconnect the RTU-292C from all other equipment and connect the test equipment as shown
in Figure 5-1, except use an audio signal generator in place of the noise generator.
2. . Set the PSTN levels for -9 dBm using Option SW2-1, -2, and -3.
3. Start with the following pushbuttons OFF: TEL LINE/PHONE, TEL LINE/RADIO, and TEL
VOX. The positions of the other buttons are unimportant. Place the RTU-292C in set-up mode
by setting SW2-7 ON and then turning on the power. (See Section 2.10.1 for further details about
set-up mode.)
4. Adjust the TX Level Adjust, R133, so that the audio voltmeter reads -6dBm (0.387V rms).
This sets the transmit signal output path in the RTU-292C for unity gain.
5. Set the output amplitude of the audio signal generator to about 0dBm (0.775V rms). Adjust
the RX Level Adjust so that the PEAK LED just comes on. This will set the average noise level
into the RTU-292C’s hybrid to approximately 0dBm.
6. Remove the unit from Set-up Mode by turning the RTU-292C Main Power OFF, setting SW2-
7 OFF, then turning the main power back ON.
7. Set the audio generator frequency to about 1 kHz.
8. Push the TEL LINE/RADIO button to start the adaptation cycle.
9. When the initial adaptation cycle is complete, the tone output can be read on the audio
voltmeter. The voltage should be typically less than -50dBm (2.5mV). The trans-hybrid loss is
the difference between this reading and the approximate 0dBm tone level.
NOTE
The reading should be made as soon as the adaptation cycle is complete. The RTU-
292C continuously adapts itself to the conditions to which it is exposed. With the
single tone input presented by this test, the unit will eventually adapt to reject only
this single tone instead of the intended broad range of frequencies. This may take
several seconds to several minutes, and an erroneous reading will result when this
happens. The reading will always be correct (and an accurate depiction of operation
under normal conditions) immediately following the initial adaptation cycle, since
the unit has adapted broad band using its own noise source, and has not yet had
time to adapt to the single tone only.
10. To measure the unit at a different frequency, change the audio generator frequency and repeat
steps 8 and 9.
Summary of Contents for RTU-292C
Page 4: ...RTU 292C Operations Manual 4 Blank Page...
Page 12: ...RTU 292C Operations Manual 12 This page intentionally left blank...
Page 35: ...RTU 292C Operations Manual 2 17 Figure 2 1 Outline Dimensions...
Page 37: ...RTU 292C Operations Manual 2 19 Figure 2 3 Location of Internal Option Settings...
Page 38: ...RTU 292C Operations Manual 2 20 Figure 2 4 Internal Option Settings Details...
Page 39: ...RTU 292C Operations Manual 2 21 Figure 2 5 Audio Interface Wiring Diagram...
Page 40: ...RTU 292C Operations Manual 2 22 Figure 2 6 Interface Details...