ACU-5000 Operations Manual
6-4
Interoperability Now
Deselect Net Button (after action)
If 'yes', when performing net-based operations (combining/separating/disbanding nets), the
selected net control button is automatically de-selected. (Net Groups are often comprised of just
2 nets, so enabling this can save a click. However, this will require extra clicks when additional
net operations are needed.)
6.2.2
Net Control - Multi-Channel Click Behaviors
These preferences involve how the system responds to clicking on one channel after another.
These behaviors can be different based on the situation the channel is in:
When Both Channels Are Free
Applicable when both channels are in the 'Free' net. When in this situation, 1 of 2 behaviors may
be applied:
•
Move Both To New Net - Moves both channels to an unoccupied net.
•
Priority Connect - Establishes a priority connection between the two channels, but leaves
them both in the 'Free' net.
When One Is Free, One Is In A Net
Applicable when one channel is in the 'Free' net and one channel is in any other net. When in this
situation, 1 of 3 behaviors may be applied:
•
Move Both to New Net - Moves both channels to a separate unoccupied net.
•
Priority Connect - Establishes a priority connection between the two channels, but leaves
them in the nets they are in (one in the 'Free' net, one in another net).
•
Join Occupied Net - The channel in the 'Free' net will be moved to the net the other
channel is in.
When Both Channels Are In Nets
Applicable when both channels are in nets, neither of which are in the 'Free' net. When in this
situation, 1 of 2 behaviors may be applied:
•
Move Both to New Net - Moves both channels to a separate unoccupied net.
•
Priority Connect - Establishes a priority connection between the two channels, but leaves
them in the nets they are in.
Summary of Contents for ACU-5000
Page 8: ...ACU 5000 Operations Manual 8 Interoperability Now blank page...
Page 22: ...ACU 5000 Operations Manual 2 6 Interoperability Now End of Section 2...
Page 38: ...ACU 5000 Operations Manual 4 12 Interoperability Now End of Section 4...
Page 40: ...ACU 5000 Operations Manual 5 2 Interoperability Now...
Page 46: ...ACU 5000 Operations Manual 5 8 Interoperability Now...
Page 62: ...ACU 5000 Operations Manual 6 12 Interoperability Now End of Section 6...
Page 86: ...ACU 5000 Operations Manual 10 2 Interoperability Now End of Document...