background image

29

30

Electromagnetic Compatibility Information

Electromagnetic Compatibility Information

27

28

The device satisfies the EMC requirements of the international 
standard IEC 60601-1-2.The requirements are satisfied under the 
conditions described in the table below.The device is an electrical 
medical product and is subject to special precautionary measures 
with regard to EMC which must be published in the instructions 
for use.Portable and mobile HF communications equipment can 
affect the device.Use of the unit in conjunction with non-approved 
accessories can affect the device negatively and alter the 
electromagnetic compatibility.The device should not be used 
directly adjacent to or between other electrical equipment.

Electromagnetic Compatibility Information

This device complies with part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 
(1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including 
interference that may cause undesired operation. 
The device has been evaluated to meet general RF exposure 
requirement. The device can be used in portable exposure 
condition without restriction.

FCC Information

Summary of Contents for DET-306b

Page 1: ...itute for consultation with your physician 4 some parts are small enough to be swallowed 5 Never immerse this device in water or other liquids not waterproof 6 Do not modify this equipment without authorization of manufacturer 7 Do not expose the thermometer to temperature extremes below 25 13 or over 55 131 nor excessive humidity 95 RH 8 Keep the battery away from children 1 There is no gender or...

Page 2: ... For Use The real time clock will be recorded with the memory function and help you to recognize each measurement result Please see the Real time clock setting section to learn how to setup the time in the first use The thermometer has been designed for practical use It s not meant to replace a visit to the doctor Please also remember to compare the measurement result to your regular body temperat...

Page 3: ...l This is the only way to accurately diagnose a fever To determine normal temperature take multiple readings when healthy Re measure with a standard digital thermometer for confirmation 2 Users 3 Oils or cosmetics on the forehead may give a lower temperature reading than the actual one must be inside for 30 minutes before taking a measurement Note Users and the thermometer should be in the same am...

Page 4: ... a reading equal to or higher than 37 8 100 0 In Object mode The display will only be lighted GREEN for 3 seconds when the unit is ready for measurement and a measurement is completed 1 Press the BUTTON The display is activated to show all segments 3 Read the temperature on the display 4 Press the BUTTON to turn off After self checking Figure 2 appears on the display screen with beeps so you can s...

Page 5: ...to the EMC information Do not put the thermometer into water directly 7 Put the thermometer back to the original packaging after using 15 Match your with a Smart Device 1 If this is your first time using it bind first Open SETTING menu choose Bind and unbind device and select the appropriate model The date and time on your thermometer will automatically be updated when it s connected with your pho...

Page 6: ...ry cover down as shown in Figure 10 3 Remove battery and install 2 new AAA alkaline batteries as shown in Figure 11 4 Slide battery cover back on Figure 9 Figure 10 Figure 11 Specifications Forehead mode 34 0 43 0 93 2 109 4 Object mode 0 100 32 212 Forehead mode 0 2 0 4 during 35 5 42 0 95 9 107 6 at 15 35 59 0 95 0 operating temperature range 0 3 0 5 for other measuring and operating temperature...

Page 7: ...vice to the dealers or manufacturer The above recommendations do not supersede the legal requirements The user must always comply with legal requirements for the control of the measurement functionality and accuracy of the device which are required by the scope of relevant laws directives or ordinances where the device is used A clinical summary and procedures for checking calibration are availabl...

Page 8: ...e Use of the unit in conjunction with non approved accessories can affect the device negatively and alter the electromagnetic compatibility The device should not be used directly adjacent to or between other electrical equipment Electromagnetic Compatibility Information This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cau...

Page 9: ...d in the frequency range 80 MHz to 2 7 GHz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges c Field stre...

Page 10: ...or radio control products If you have to do so the device should be observed to verify normal operation The use of accessories and power cord other than those specified with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components may result in increased emissions or decreased immunity of the equipment or system ...