COMPLETE INSTRUCTION MANUAL

Weekly Wi-Fi Programmable Thermostat

Summary of Contents for GCW03MR001SE

Page 1: ...wi time wall COMPLETE INSTRUCTION MANUAL Weekly Wi Fi Programmable Thermostat ...

Page 2: ......

Page 3: ...NTI FROST Antifreeze 10 P02 OFFSET Room temperature offset indoor sensor or remote sensor if connected 10 P03 HYST hysteresis setting 10 P04 PROP BAND Proportional band 11 P05 INTEGR TIME Integrative time 11 P06 TMIN HEAT Minimum heating temperature 11 P07 TMAX HEAT Maximum heating temperature 11 P08 TMIN COOL Minimum cooling temperature 11 P09 TMAX COOL Maximum cooling temperature 11 P10 MODBUS I...

Page 4: ...GCW03MR001SE 040088 230922 4 ...

Page 5: ...85 bus with MODBUS RTU protocol The RS485 bus is available at terminals 9 A and 8 B The signals relating to the RS485 port are insulated with double insulation in relation to the power supply terminals L and N and the output relay termin It is necessary to tie toghether the cable groups with cable ties separating the power and load wires from those of the bus to avoid that if a wire is accidentall...

Page 6: ...ds PAIRING hold down the button for 5 seconds the words PAIRING change to SKIP then the display switches to the minimal display WARNING When the wi time wall is not paired with the App the only available room temperature control modes are manual and antifreeze If temporary manual mode is selected the programmable thermostat will carry out temperature adjustment in the same way as permanent manual ...

Page 7: ... MODE Press the button once the wi time wall programmable thermostat shows the current operation mode active on that moment this function is only available on the minimal display mode By pressing the button further it is possible to modify the operation mode of the wi time wall programmable thermostat choosing among the 4 different modes Program Manual Temporary Manual Permanent Antifreeze or OFF ...

Page 8: ...rmostat select the OFF operating mode by repeatedly pressing the WARNING In the case where the programmable thermostat is set in heating mode it is necessary for the anti freeze parameter to be set to OFF see chapter ADVANCED CONFIGURATION ANTIFREEZE FUNCTION The antifreeze function is activated if the programmable thermostat is on and the following three conditions are true at the same time 1 The...

Page 9: ...ith which it will communicate via RS485 bus with MODBUS RTU protocol In this way both relay output status and proportional status can be read to perform proportional modulating control For more information on the mode of operation and MODBUS communication protocol you should contact your local distributor ...

Page 10: ...elected will be completely off OFF To adjust the antifreeze temperature perform the following steps 1 Having selected the ANTI FROST parameter adjust the desired antifreeze temperature with the and or buttons the setting is saved automatically 2 Press the key to select the next parameter or wait 15 sec without pressing any key P02 OFFSET Room temperature offset indoor sensor or remote sensor if co...

Page 11: ...u wish to set obviously it must be a lower value than the temperature set on TMAX HEAT the setting is saved automatically 2 Press the key to select the next parameter or wait 15 sec without pressing any key P07 TMAX HEAT Maximum heating temperature Adjusts the maximum temperature that can be set in normal operation using the and buttons when the wi time wall programmable thermostat is set in Heati...

Page 12: ... parameter press and hold the button for at least 10 seconds 2 The display of the wi time wall shows WI FI CONFIG OK 3 After a few moments the programmable thermostat will restart and the Pairing screen will appear for 2 minutes the display shows and the words PAIRING 4 Proceed as described in the chapter PAIRING PROGRAMMABLE THERMOSTAT APP WARNING In the event that power is lost to the device and...

Page 13: ...2 C 25 0 C Default 3 0 C Temp sensor offset 5 0 C Default 0 0 C Protection grade IP 30 Type of action 1 Overvoltage category II Pollution degree 2 Tracking Index PTI 175 Class of protection against electric shock II Rated impulse voltage 2500V Number of manual cycles 1 000 Number of automatic cycles 100 000 Software class A EMC test voltage 230V EMC test current 25mA Distances tolerances fault mod...

Page 14: ...r reserves the right for changing technical data and features without prior notice The consumer is guaranteed against any lack of conformity according to the European Directive 2019 771 UE as well as to the manufacturer s document about the warranty policy The full text of warranty is available on request from the seller ...

Page 15: ......

Page 16: ...SEITRON S p A a socio unico Via del Commercio 9 11 36065 Mussolente VI ITALY 39 0424 567 842 info seitron it www seitron com ...