background image

Instruction Manual

HI 98710 • HI 98810
HI 98740 • HI 98840

Printing and Logging

Thermometers

Summary of Contents for HI 98710

Page 1: ...Instruction Manual HI 98710 HI 98810 HI 98740 HI 98840 Printing and Logging Thermometers...

Page 2: ...re than one probe is used the printer will label the data of each probe HI 98810 and HI 98840 combine the high accuracy and fast re sponse time of the HI 98710 series with an extensive logging feature...

Page 3: ...be transferred to a PC by placing the instrument on the HI 9200 infrared interface connected to the computer serial port The connection is handled with the HI 92000 Windows com patible software from H...

Page 4: ...continue to monitor the temperature periodically at the end of every logging interval Only the LOG indication will be visible on LCD While storing data in memory during the sleep mode the reading will...

Page 5: ...on of the specific setup items their valid values and the factory settings default Code Valid values Default 00 Lot data printing scrolling1 00 to 16 00 01 Logging interval 1 2 5 10 15 30 60 120 180 1...

Page 6: ...CD will display the sample number being printed at that moment If printout is stopped the LCD will show the last printed sample number It is then possible to select another sample Press the ALT and FN...

Page 7: ...ill display bAtt on the upper display and the remaining percentage of battery charge 100 means fully charged battery and 0 cor responds to the minimum battery voltage that allows the meter to operate...

Page 8: ...8810 HI 98840 PRINTING LOGGING FUNCTIONS To prepare the instrument for use choose the most appropriate tem perature probe s for your application see accessories and connect it them to the connector s...

Page 9: ...r TEMP TIME HI98810 only TO STOP LOGGING In order to stop the recording mode press ALT and LOG keys press ON OFF first if meter is in sleep mode A last printout reporting the number of logged samples...

Page 10: ...r attempts to print while in low battery condition the message bAtt will appear for a few seconds on the LCD Note It is possible to reset the sample number of the print on demand to 001 see TO RESET P...

Page 11: ...a few minutes to follow the instructions conveniently printed on the disk label DATA TRANSFER TO PC HI 98810 HI 98840 only OTHER FEATURES LCD BACKLIGHT The backlit LCD allows the user to operate even...

Page 12: ...t data are erased without any warning message Note Timed logging memory can be entirely erased through the setup code 06 If the meter is powered only by the external power supply and there is a tempor...

Page 13: ...batteries are inserted or an external power adapter is connected 3 Weak batteries LOBAT symbol stays still on lower LCD Backlight and printer are disabled and meter can work for about 20 hours If in T...

Page 14: ...nstruments offers a wide line of NTC thermistor sensors that can be custom mounted in almost any situation Select the sensor that matches your application attach it to the RCA adaptor and plug it into...

Page 15: ...g to instructions The electrodes and the probes are warranted for a period of six months This warranty is limited to repair or replacementfreeofcharge Damagesduetoaccident misuse tamperingorlack of pr...