To measure object temperature:

1. 

    the object temperature after hearing two beep sounds.(see figure 5) 

2. Aim the thermometer at the center of the object you want to 

    measure with a distance 

e temperature on the 

    display.

4. Press the      

BUTTON

  to turn off.

Press the       

BUTTON  

to turn on the thermometer, you can take

 less than 5cm. 

3. Press the 

START BUTTON

 and then read th

Figure 5

How to change the forehead mode and object mode:

You can press 

      /       BUTTON

 

 

to switch the mode between 

Forehead mode and Object mode.

After measurement:

1.  Power off: Device will automatically shut off if left idle for 

     more than 1 minute to extend battery life.

2.  Clean the probe after each use to ensure an accurate reading and

     avoid cross contamination. 

     (See the section of Care and Cleaning for details.) 

BackLight:

In Forehead mode:

1. The display will be lighted GREEN for 3 seconds with a happy 

    face       when the unit is ready for measurement and a measurement

    is completed with a reading less than 37.3

(99.1 ).

2. The display will be lighted YELLOW for 3 seconds with a happy 

    face      when a measurement is completed with a reading less than

    37.8

(100.0 ).

3. The display will be lighted RED for 3 seconds with a bad face 

    when a measurement is completed with a reading equal to or higher 

    than 37.8

(100.0 ).

In Object mode:

    

The display will only be lighted GREEN for 3 seconds when the

     unit is ready for measurement and a measurement is completed.

1. Press the       BUTTON,  The display is activated to show all 

    segments. 

3. Read the temperature on the display.

4. Press the      BUTTON to turn off.

After self-checking Figure 2 appears on the display 

    screen with beeps, so you can start a new measurement. 

2. Aim the thermometer at the center of the forehead with a distance

    less than 5cm (See figure 3) and then press the START BUTTON.

    Note1: Do not remove the thermometer from the forehead before

    hearing the final beep. A waiting period of 1 seconds between 

    testing is recommended to ensure complete accuracy.

    Note2:If the object to be tested is too far from the probe, a 

    prompt will appear(See figure 4).

To measure forehead temperature:

Figure 3

Figure 2

Figure 4

14

    

Bluetooth requirements

The thermometer requires a bluetooth device with:

    . Bluetooth 4.0 or later

    . Android 6.0 or later

    . IOS 8.0 or later 

And works with:

     . iphone , iPod, iPad

     . Android Phones and Tablets

    Using for the first time

1. Download the "JoyHeath" App from Website or APP  Store (Such 

    as Apple Store).

2.Open the App on your phone or tablet. If requested, you should

     enable Bluetooth on your device. You can enable Bluetooth under 

     the Settings menu on your  smart phone or tablet.

3. Create a new user login, or login with your existing user name and 

    password.  

4. Selection device  “Thermometer”.

Illustration For Use

Summary of Contents for DET-306b

Page 1: ...itute for consultation with your physician 4 some parts are small enough to be swallowed 5 Never immerse this device in water or other liquids not waterproof 6 Do not modify this equipment without authorization of manufacturer 7 Do not expose the thermometer to temperature extremes below 25 13 or over 55 131 nor excessive humidity 95 RH 8 Keep the battery away from children 1 There is no gender or...

Page 2: ... For Use The real time clock will be recorded with the memory function and help you to recognize each measurement result Please see the Real time clock setting section to learn how to setup the time in the first use The thermometer has been designed for practical use It s not meant to replace a visit to the doctor Please also remember to compare the measurement result to your regular body temperat...

Page 3: ...l This is the only way to accurately diagnose a fever To determine normal temperature take multiple readings when healthy Re measure with a standard digital thermometer for confirmation 2 Users 3 Oils or cosmetics on the forehead may give a lower temperature reading than the actual one must be inside for 30 minutes before taking a measurement Note Users and the thermometer should be in the same am...

Page 4: ... a reading equal to or higher than 37 8 100 0 In Object mode The display will only be lighted GREEN for 3 seconds when the unit is ready for measurement and a measurement is completed 1 Press the BUTTON The display is activated to show all segments 3 Read the temperature on the display 4 Press the BUTTON to turn off After self checking Figure 2 appears on the display screen with beeps so you can s...

Page 5: ...to the EMC information Do not put the thermometer into water directly 7 Put the thermometer back to the original packaging after using 15 Match your with a Smart Device 1 If this is your first time using it bind first Open SETTING menu choose Bind and unbind device and select the appropriate model The date and time on your thermometer will automatically be updated when it s connected with your pho...

Page 6: ...ry cover down as shown in Figure 10 3 Remove battery and install 2 new AAA alkaline batteries as shown in Figure 11 4 Slide battery cover back on Figure 9 Figure 10 Figure 11 Specifications Forehead mode 34 0 43 0 93 2 109 4 Object mode 0 100 32 212 Forehead mode 0 2 0 4 during 35 5 42 0 95 9 107 6 at 15 35 59 0 95 0 operating temperature range 0 3 0 5 for other measuring and operating temperature...

Page 7: ...vice to the dealers or manufacturer The above recommendations do not supersede the legal requirements The user must always comply with legal requirements for the control of the measurement functionality and accuracy of the device which are required by the scope of relevant laws directives or ordinances where the device is used A clinical summary and procedures for checking calibration are availabl...

Page 8: ...e Use of the unit in conjunction with non approved accessories can affect the device negatively and alter the electromagnetic compatibility The device should not be used directly adjacent to or between other electrical equipment Electromagnetic Compatibility Information This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cau...

Page 9: ...d in the frequency range 80 MHz to 2 7 GHz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges c Field stre...

Page 10: ...or radio control products If you have to do so the device should be observed to verify normal operation The use of accessories and power cord other than those specified with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components may result in increased emissions or decreased immunity of the equipment or system ...

Reviews: